A-1 Research on the "Task and Ambient" Air Cleaning System (Part. 10 Efficient treatment method of the high temperature heat from equipment) Hisashi Hasebe, Yoshinobu Suzuki, Yoko Yamada Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 1-3, 2012. |
---|
![]() |
A-2 Research on the "Task and Ambient" Air Cleaning System (Part. 11 Particle generation from motors in FFU and FCU) Yoshinobu Suzuki, Hisashi Hasebe Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 4-6, 2012. |
---|
![]() |
A-3 Research on Environment Control Technologies of New Clean Room Part3. Measurement of Non-isothermal Flow Field Induced by High-temperature Heat Source Eikichi Ono, Takamasa Hasama, Masaki Shioya, Yuichi Takemasa, Masahiro Kato Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 7-9, 2012. |
---|
![]() |
A-4 Research on Environment Control Technologies of New Clean Room Part4. Large-Eddy Simulation of Non-isothermal Flow Field Induced by High-temperature Heat Source Takamasa Hasama, Eikichi Ono, Masaki Shioya, Yuichi Takemasa, Masahiro Kato Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 10-12, 2012. |
---|
![]() |
A-5 Study on Improvement in Sensitivity of a QCM Surface-Modification-Type Sensor for Clean Rooms Isao Tanaka, Yoko Yamada, Masahide Goto, Tomoharu Fujita, Tomoaki Kajima Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 13-15, 2012. |
---|
![]() |
A-6 Development of air-conditioning system that suppresses energy consumed according to dehumidification load, part 2 Daisuke Sugata*1, Takeshi Ebine*1, Hajime Tamura*2 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 16-18, 2012. |
---|
![]() |
A-7 An Experimental Study on the Preventive Schemes for Water Damages of Fan Dry Coil Unit (FDCU) System 柯宜松*1, 邱俊榮*1, 張振光*1, Angus Shiue*1, 胡石政*1, 戸田幸司*2 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 19-22, 2012. |
---|
![]() |
Low-Carbon Society and Net-Zero Energy Buildings Yuzo Sakamoto Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 23-35, 2012. |
---|
![]() |
A-8 Influence of Application of Sorptive Building Materials on Decrease in Indoor Toluene Concentration Sunghyun Park, Janghoo Seo Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 36-38, 2012. |
---|
![]() |
A-9 Complete decomposition of 2-propanol using TiO2 photocatalyst and ozone microbubbles Kazuhiko Sekiguchi*1, Takeshi Yoshida*1, Qingyue Wang*1, Kim Kyung Hwan*2, Fumio Yasui*3, Hajime Tamura*3, Tatsuya Kawasaki*4, Yasuko Matsubayashi*4 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 39-41, 2012. |
---|
![]() |
A-10 VOC gas degradation using a fixed ozone-decomposition catalyst under ozone existence condition Kazuhiko Sekiguchi*1, Yuki Kurita*1, Norikazu Namiki*2, Naoki Kagi*3, Shuji Fujii*3, Kenichi Azuma*4, Hajime Tamura*5, Yoshihide Suwa*6 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 42-44, 2012. |
---|
![]() |
A-11 Development of the reproduction equipment for the removal solution which absorbs IPA gas by vacuum evaporation with air flow Tomoyuki Kojima, Keita Katsumaru, Tetsurou Kitae, Shigeru Tanaka Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 45-47, 2012. |
---|
![]() |
A-12 Development of removal technology for IPA (IsoPropyl Alcohol) in exhaust gas by spraying removal solution with PUF (Poly Urethane Foam) Tomohiro Nagata, Ryo Kato, Daisuke Matsushita, Shigeru Tanaka Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 48-49, 2012. |
---|
![]() |
A-13 Characterization of removal of volatile organic compounds (VOCs) in exhaust gas using APA (acrylamide polyampholyte)-containing mists atomized by spray nozzles Yu Oshikubo, Tsuyoshi Takagi, Ken Tokunaga, Norikazu Namiki, Naoki Kagi*2, Tatsuo Morita*3, Takashi Okubo*3, Michifusa Manabe*3, Shunsuke Kobayashi*4 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 50-52, 2012. |
---|
![]() |
A-14 Evaluation of collection efficiency of oil-mist elimination filters Shouji Hirota, Keiji Hori, Masaji Miyoshi, Keisuke Kotani Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 53-55, 2012. |
---|
![]() |
A-15 Round Robin Test Report for Air Filter based on JIS B9908 (2011) Yutaka Ogaki, Toshiaki Hayashi, Norikazu Shinya, Shoji Hirota Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 56-57, 2012. |
---|
![]() |
A-16 Morphology-controlled synthesis of electrospun nanofiber and their application for aerosol filtration Hitomi Ono*1, Shoji Nakai*1, Takashi Ogi*1, Kikuo Okuyama*1, Yoshio Otani*2, Li Bao*3, Hitoshi Niinuma*3 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 58-59, 2012. |
---|
![]() |
A-17 Synthesis and characterization of WO3 photocatalyst prepared by flame assisted spray pyrolysis method Takashi Ogi*1, Kikuo Okuyama*1, Agus Purwanto*2 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 60-61, 2012. |
---|
![]() |
B-1 The performance of the plasma deodorization equipment for smoking rooms, and the influence on indoor air quality Nobuhiko Tamaki*1, Shuji Fujii*2, Naoki Kagi*2, Kousuke Mori*2 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 62-64, 2012. |
---|
![]() |
B-2 A suggestion on new air cleaning device using with chemical additive agent an air freshener (Part 1) Atsuo Nozaki, Yusuke Ichijo, Yasunori Narita Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 65-66, 2012. |
---|
![]() |
B-3 A suggestion on new air cleaning device using with chemical additivi agent an air freshener (Part 2) Atsuo Nozaki, Yasunori Narita, Yusuke Ichijo Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 67-68, 2012. |
---|
![]() |
B-4 A suggestion on new air cleaning device using with chemical additive agent an air freshener (Part 3) Atsuo Nozaki, Yusuke Ichijo, Yasunori Narita Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 69-70, 2012. |
---|
![]() |
B-5 Field Survey of Indoor Air Quality in University Classrooms Yanagi U*1, Kagi N*2, Osawa H*3 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 71-74, 2012. |
---|
![]() |
B-6 Field surveys on indoor air qualities in various sorts of restaurants with Smoking permission and a proposal of their preservation Tsuyoshi Takagi*1, Norikazu Namiki*1, Hiroyuki Ito*2, Takahiro Kuwabara*2, Kiyomi Sakai*2 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 75-77, 2012. |
---|
![]() |
B-7 Dynamic behaviors of environmental tobacco smoke at the interface installed with a sliding door with louvers Takahiro Uda*1, Norikazu Namiki*1, Naoki Kagi*2 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 78-80, 2012. |
---|
![]() |
B-8 New Humidification System by Use of H2O Gas (Superheated Steam) Dai Aramaki, Yoshinobu Murakami, Sinsuke Ohara, Hiroshi Nagasawa Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 81-83, 2012. |
---|
![]() |
B-9 Study of aerosol pollution detection from the time variation in aerosol number concentration, and its application Tadashi Okada, Shuji Fujii, Yuzuru Hayashi Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 84-86, 2012. |
---|
![]() |
B-10 Examination of air-conditioning system contamination and proposal of assessment guideline (3) Susumu Shimizu, U Yanagi, Fumio Kano, Kosuke Takatori, Shoji Yamazaki Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 87-88, 2012. |
---|
![]() |
B-11 Application of Molecular Orbital Computation on the Study of ISOA Yoshihide Suwa*1, Yuiko Yamane*2, Naoki Kagi*2, Shuji Fujii*2, Norikazu Namiki*3, Kazuhiko Sekiguchi*4, Kenichi Azuma*5, Hajime Tamura*6 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 89-91, 2012. |
---|
![]() |
B-12 Secondary organic aerosol formation from VOCs with UV irradiation in the indoor air Yuiko Yamane※1, Shuji Fujii※1, Naoki Kagi※1, Daiki Matsushita※2, Yukari Nakamura※2, Yusuke Sugai※2, Norikazu Namiki※2, Yoshihide Suwa※3, Kazuhiko Sekiguchi※4, Kenichi Azuma※5, Hajime Tamura※6 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 92-94, 2012. |
---|
![]() |
B-13 Attempt to elucidate the mechanism for ultrafine particle generation from laser printers using model vapors Norikazu Namiki*1, Megumi Ebiduka*1, Naoki Kagi*2, Kazuhiko Sekiguchi*3, Kenichi Azuma*4, Hajime Tamura*5, Yoshihide Suwa*2, Shuji Fujii*2 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 95-97, 2012. |
---|
![]() |
B-14 Cleanbooth with Return Air System Yoshihide Suwa Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 98-100, 2012. |
---|
![]() |
B-15 Research on Task Air Cleaning System for BCR Operating Room Part2. Results of CFD Simulation for vacuum or air supply system set in shadowless light Yoko Yamada*1, Tomoaki Kajima*1, Koichi Isawa*1, Yasuhiro Miura*1, Makoto Yamaguchi*1, Isao Tanaka*1, Yoshinobu Suzuki*2 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 101-102, 2012. |
---|
![]() |
B-16 Experimental Study on Room Pressure Control at Cleanroom Yukitada MURAE, Tamio IWAMURA, Shigeru KURIKI, Hiroyuki NAGAI, Koji NAGANO, Natsuki Kubo Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 103-105, 2012. |
---|
![]() |
B-17 Development of high-speed variable air volume control system differential pressure sensing - Accuracy of orifice-type air flow meter - Yoshiharu Izumi, Kazuhiko Shimizu, Hajime Tamura, Ryousei Ogawa Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 106-108, 2012. |
---|
![]() |
A-18 Measurement of SVOC concentration in House Hyun-tae Kim*1, Shin-ichi Tanabe*2 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 109-110, 2012. |
---|
![]() |
A-19 A consideration on analytical method of styrene in indoor air using charcoal tube collection / carbon disulfide extraction / GC-MS method Toshiro Matsumura, Naoki Maeda, Kenji Yoshikawa, Yukitoki Morita, Akio Sakuragawa Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 111-112, 2012. |
---|
![]() |
A-20 Simultaneous determination method of nitrogen dioxide and aldehyde in indoor air using HPLC Toshiro Matsumura*1, Miki Muramatsu*1, Kenji Yoshikawa*1, Yukitoki Morita*1, Akio Sakuragawa*1, Reiji Aoyagi*2, Kunitoshi Matsunobu*2, Yuichiro Kaifuku*2 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 113-114, 2012. |
---|
![]() |
A-21 Sensitive evaluation of airborne anion contaminants with short-time sampling using the solid phase sampler Yuko Ishiwata, Itsuka Shimada, Tetsuya Saegusa, Masashi Murakami, Taketoshi Fujimoto Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 115-116, 2012. |
---|
![]() |
A-22 Development of evaluation tool for airborne molecular contamination in the micro-environment related with photomask Mina Douzono, Ikue Nagatani, Itsuka Shimada, Tetsuya Saegusa, Masashi Murakami, Taketoshi Fujimoto Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 117-119, 2012. |
---|
![]() |
A-23 New VOC recovery test method of emission test chambers for equipments using consumables Yukio Adachi*1, Daisuke Miyata*1, Yoshito Inatomi*2, Ayako Ogawara*3, Hirofumi Kawaguchi*4, Tomohiro Kimura*5, Kazumi Kuwata*6, Shouichi Nakano*7, Yoshikazu Nishihara*7, Kazushi Fukuta*8, Koichi Watanabe*9 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 120-122, 2012. |
---|
![]() |
A-24 Removal Performance for Radioactive Substances by Ventilating Air Purification System with Water as a Cleaning Medium Masashi Fujita, Yuta Doi, Koji Yamanaka Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 123-124, 2012. |
---|
![]() |
A-25 Measurement of the air dose rate and the database of air radiation measurements in Japan Mizuki Inoue, Shuji Fujii Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 125-126, 2012. |
---|
![]() |
A-26 Simple Valuation Method of Radioactivity on an Air Filter Caused by Fukushima Nuclear Accident. Hitoshi Nakatsuka*1, Norio Nomoto*2, Satoki Sugiyama*2 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 127-129, 2012. |
---|
![]() |
Guideline for Air Filter Contaminated by Radioactive Materials Michikuni SHIMO, Masayasu INOHARA, Takahiro TOMIOKA, Norio NOMOTO, Yoshihisa FURUKAWA Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 130-143, 2012. |
---|
![]() |
A-27 Development of Personal Sampler for Ambient Nano-particles Thunyapat Thongyen*1, Masami Furuuchi*1, Mitsuhiko Hata*1, Yoshio Otani*1, Masaru Kusunoki*1, Takuji Ikeda*2 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 144-145, 2012. |
---|
![]() |
A-28 Development of High Volume Sampler for Ambient Nano-particles Masami Furuuchi*1, Yoshio Otani*1, Aiko Hoshino*1, Mitsuhiko Hata*1, Takuji Ikeda*2 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 146-147, 2012. |
---|
![]() |
A-29 Study of assessing the containment performance of open type isolator for high physiologically active substances Masahiro Sato, Kenji Takagi Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 148-151, 2012. |
---|
![]() |
A-30 A study of an evaluation technique of the hazardous particulate containment performance in the facilities for highly active medicals (Part2) Kentaro Amano, Satoshi Saito, Hideaki Tani, Takeshi Ishiguro Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 152-153, 2012. |
---|
![]() |
A-31 Study on evaluation method of the amount of scattered carbon nanotube Part 3 A case study of the evaluation at CNT handling workplace Hideaki Tani, Takeshi Ishiguro, Naohiro Kobayashi Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 154-157, 2012. |
---|
![]() |
A-32 Characterization of collection of nanomaterial-derived particles by inertial samplers using the vibrated-hopper particle generator Yuichi Osuga*1, Tsuchio Tsukamoto*1, Norikazu Namiki*1, Naoki Kagi*2, Hirofumi Fujii*3, Yasuko Yoshida*3 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 158-160, 2012. |
---|
![]() |
A-33 Evaluation of particle separation performance of virtual impactor for PM10 / PM2.5 measurements via number concentration counting and its application to field measurements at stationary particle emission sources Tohru Ohishi*1, Norikazu Namiki*1, Masashi Wada*2, Miyo Arai*3, Mayumi Tsukada*3, Hidehiro Kamiya*3, W. W. Szymanski*4 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 161-163, 2012. |
---|
![]() |
A-34 Electrostatic collection of ultrafine particles using ultrasonically atomized mists Norikazu Namiki*1, Kaoru Sasahara*1, Kazuhiko Sekiguchi2* Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 164-166, 2012. |
---|
![]() |
B-18 Study of ion characteristics generated by ionizers in cleanroom Yoshihide Suwa*1, Weiguang Chen*2, Shuji Fujii*2, Takao Hayashi*3, Katsumi Matsuba*3, Hajime Tamura*4, Masanori Suzuki*4, Tomokatsu Sato*4 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 167-169, 2012. |
---|
![]() |
B-19 Development of particle-free ionizer preventing impurities in the air from depositing on discharge electrodes by thermophoretic force Masanori Suzuki, Tomokatsu Sato Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 170-172, 2012. |
---|
![]() |
B-20 Analysis of Ions Generated by Corona Discharge Type Ionizer in Indoor Environment Kenkichi Nagato*1, Tatsumi Enokida*2, Yoshio Okamoto*2 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 173-174, 2012. |
---|
![]() |
B-21 Behavior of adsorption of airborne nanoparticle on wafer Eri Uemura, Tsunekazu Yasutake, Noboru Okamoto, Makiko Tamaoki, Kazuhiro Nishiki Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 175-177, 2012. |
---|
![]() |
B-22 High-efficiency and high-throughput charging of nanoparticles Yoshio Otani, Eric Manirakiza, Takafumi Seto Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 178-180, 2012. |
---|
![]() |
B-23 Survey of Drainage Slime and Evaluation of Antimicrobial Agent for Air Conditioner Hiroki Arakawa, Hideto Takahashi, Hitoshi Inaba, Hiroshi Gomi Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 181-183, 2012. |
---|
![]() |
B-24 Study on Microbial Contamination-Control of Evaporative Humidifier for Air Conditioning System Using Electrolyzed Water Part 1 Kazuya TAMURA*1, Shoichi NAKAI*1, Kaoru GOTO*1, Koichi IKEDA*2 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 184-187, 2012. |
---|
![]() |
B-25 Study on Sterilization of Surface Colonized Bacteria by Atmospheric Microplasma Shigeki Tatematsu, Marius Blajan, Kazuo Shimizu Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 188-189, 2012. |
---|
![]() |
B-26 Microbial cleaning of metal ion containing solution Yuma Sakamoto, Takashi Ogi, Kikuo Okuyama Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 190-191, 2012. |
---|
![]() |
B-27 Study of scattering of fungi grown on the surface of concrete materials Satoshi Saito, Takeshi Ihara Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 192-193, 2012. |
---|
![]() |
B-28 A Study on the Behavior of indoor microbial contamination in 7 houses Yanagi U*1, Kagi N*2, Osawa H*3, Yotsumoto M*4, Ogata H*5 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 194-197, 2012. |
---|
![]() |
B-29 The actual condition and the measure against air pollution in a construction field Shinichiro Ozao Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 198-199, 2012. |
---|
![]() |
B-30 Examination of the Anti-microbe Measure with the Chlorine-based Chemicals (Part 7) Prediction Method of Space Sterilization Performance using Local CT Value Koichi Isawa, Makoto Yamaguchi, Kazuyuki Tomioka Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 200-203, 2012. |
---|
![]() |
B-31 Biological contamination and odor problem from humidifier element of air conditioning unit Naoki KAGI*1, U YANAGI*2, Megumi ENDO*2, Yoshiaki HOSHINO*3, Kazuhiro YONEKAWA*3, Hiroyuki TAURA*3, Mitsuhiko ITO*3 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 204-206, 2012. |
---|
![]() |
B-32 Utilization of the particle counter as the rapid and simple measurement method of air-borne fungi Tohru Shimizu*1, Kosuke Takatori*1, Kanako Muramatsu*2, Yuko Kumeda*3 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 207-208, 2012. |
---|
![]() |
B-33 Investigation of contamination inside the residential exhaust ducts. Susumu Shimizu, Sumiyo Yamamoto Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 209-210, 2012. |
---|
![]() |
B-34 Study of indoor mould contamination control (Part 1). Examinations for prompt evaluations to moulds. Eriko Takehiro*1, Mizue Sawada*1, Takeshi Wakui*2 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 211-213, 2012. |
---|
![]() |
The 29th air cleanliness and contamination control study meeting held guidance 山崎省二 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 216-216, 2012. |
---|