Search by Journal
- HOME
- > Search by Journal
- > Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control
Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control
Volume , Issue suppl / 2018


- Please note that metadata of J-type articlesare generated by machine-translation and the original texts are written in Japanese.
![]() |
Characterization of PM2.5 and health effect of dust emitted from coal combustion 米持真一 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 1-4, 2018. |
---|
![]() |
Current status and future prospects of organic EL 城戸淳二 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 5-17, 2018. |
---|
![]() |
Capture of airborne ultrafine particles using droplets generated by ultrasonic atomization Norikazu Namiki*1, Kimito Nishishita*1, Ryoichi Nakayama*1, Kazuhiko Sekiguchi*2, Susumu Nii*3 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 18-21, 2018. |
---|
![]() |
Characterization of a dry surface cleaning technique using pulse air-jet blowings Ami Ishii*1, Ryoichi Nakayama*1, Norikazu Namiki*1, Hajime Tamura*2, Tomokatsu Sato*2 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 22-25, 2018. |
---|
![]() |
Formation of ultrafine particles from a fixing unit for laser printers and its suppression Norikazu Namiki*1, Yuki Nishino*1, Ryoichi Nakayama*1, Naoki Kagi*2, Hoon Kim*3, Manabu Ono*4 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 26-29, 2018. |
---|
![]() |
Influence of existing particles on indoor secondary nano-sized organic aerosol (ISOA) formation from VOCs derived from house-keeping wares Ikumi Furuya*1, Ryoichi Nakayama*1, Norikazu Namiki*1, Naoki Kagi*2, Kazuhiko Sekiguchi*3 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 30-31, 2018. |
---|
![]() |
Evaluating the Counting Efficiencies of Airborne Optical Particle Counter in Micrometer-Particle-Diameter-Range by using Inkjet Aerosol Generator Kenjiro Iida*1, Hiromu Sakurai*1, Fuminari Ito*2 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 32-33, 2018. |
---|
![]() |
CFD Analysis on Fan Filter Unit Operating Control Utilizing Motion and Particle Sensors Kosuke Kondo, Hisashi Hasebe, Masayuki Komatsubara Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 34-37, 2018. |
---|
![]() |
Clean unit system platform (CUSP) based upon 100% feed-back closed-system Akira Ishibashi*1, Nobutoshi Noguchi*2, Tsukio Etoh*3, Junji Matsuda*4, Yoshihisa Ohashi*5 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 38-41, 2018. |
---|
![]() |
Practical application of automatic and continuous measurement instrument for acidity (pH) and chemical ions in PM2.5 - Part 2 - Qiannan Zhuo*1, Wanglin Yan*1, Kozo Inoue*2, Unsei Cho*3, Akane Koyama*3, Shigeru Tanaka*3 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 42-45, 2018. |
---|
![]() |
The current situation of PM2.5 air pollution and measurement of its acidity in Beijing, China Qiannan Zhuo*1, Wanglin Yan*1, Fengkui Duan*2, Kebin He*2, Yuya Sukegawa*3, Shigeru Tanaka*3 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 46-49, 2018. |
---|
![]() |
Development of removal equipment for PM2.5 and virus by spraying electric charged mist Ryo Shimabayashi, Masahide Nagasawa, Ryoya Tabata, Shigeru Tanaka Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 50-53, 2018. |
---|
![]() |
Studies on the Deterioration of Gaseous Contaminants Removal Performance on Room Air Cleaners (Part 6) Yusuke Ichijo*1, Atsuo Nozaki*2, Yasunori Narita*3 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 54-56, 2018. |
---|
![]() |
Mainstream, side-stream, and expiration breath smoke emitted from heat-not-burn tobacco products, Part 3 Indoor air pollution caused by fine particles Atsuo Nozaki*1, Yosuke Ishii*2, Kikumi Yoshida*2 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 57-60, 2018. |
---|
![]() |
Chemical characteristics of house dust and change by ozone in residential houses Nao Maeta, Naoki Kagi Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 61-63, 2018. |
---|
![]() |
Characteristics of indoor ultrafine particles during cooking activities in residential houses Mebuki Furutani, Naoki Kagi Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 64-66, 2018. |
---|
![]() |
Analysis of odor components sensed from home electric appliances. Kei IKEDA, Noriko OKAWA, Koji KOIZUMI, Yasuko SAKAMOTO Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 67-69, 2018. |
---|
![]() |
A study on separation technique of water from solvent (NMP) by vacuum evaporation with air flow Akihiro Kobayashi, Takeshi Fukunaga, Shigeru Tanaka Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 70-73, 2018. |
---|
![]() |
Study on recycling technology using the heating desorption in physical adsorption materials such as active carbons (Part 4) Atsuo Nozaki*1, Yusuke Ichijo*2 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 74-77, 2018. |
---|
![]() |
C-8 CARBON SORBENTS FOR THE SORPTION OF TOXIC GASES Z.A.Mansurov1,2, A.R.Kerimkulova1,2, S.Azat1,2, L.F.Velasco3, P.Lodewyckx3 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 78-81, 2018. |
---|
![]() |
C-9 CATALYTIC PURIFICATION OF GASEOUS EMISSIONS FROM SULFUR OXIDES, GREENHOUSE GASES - METHANE AND CARBON DIOXIDE Mansurov Z.A.1, Dossumov K.1, Yergazieva G.Y.1, Erezhep N.2 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 82-85, 2018. |
---|
![]() |
C-10 Characterization and adsorption of potassium permanganate modified active carbon filter media for formaldehyde removal in the building environment Ying-Chun Chen1, Xin-Zhi Lin2, Po-Hua Huang3, Yen-Che Chen1, Angus Shiue4, Shih-Cheng Hu3, Shu-Mei Chang1, Bin Zhou2 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 86-89, 2018. |
---|
![]() |
Behavior and polarizability in molecules on Phthalates Yoshimi Shiramizu*1,*2 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 90-92, 2018. |
---|
![]() |
Improvement in durability of oven cleaning catalysts for PET drawing oven Naoki Tone, Toshiya Nashida Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 93-95, 2018. |
---|
![]() |
Development of Novel Hierarchical Porous Carbon "Triporous(TM)" for Air Purification Applications Shun Yamanoi, Seiichiro Tabata Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 96-99, 2018. |
---|
![]() |
A study of selective adsorption remover of trace organosilicon compounds from VOC mixture gas Makoto Shigeta*1, Yuta Irie*1, Masaya Kondo*1, Masahiko Nagata*1, Naohiro Shimoda*2, Shigeo Satokawa*2 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 100-101, 2018. |
---|
![]() |
Study on restoration of chemical substance removal performance using impregnant agents Toshiki Sakuma*1, Kikumi Yoshida*1, Atsuo Nozaki*2 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 102-103, 2018. |
---|
![]() |
Maker presentation 日本空気清浄協会 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 105-115, 2018. |
---|
![]() |
Fungus-related human health disorders : possible effect of environmental management Koichi MAKIMURA Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 117-118, 2018. |
---|
![]() |
Experimental study of the pin-hole penetration of aerosols through air-filters Seiya Suzuki, Muhammad Aiman Mohd Nor, Yoshihide Suwa Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 119-121, 2018. |
---|
![]() |
Development and evaluation of nanofiber composite air filter media Naoki Yanaoka, Takashi Nishitani, Takahiro Tomioka Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 122-124, 2018. |
---|
![]() |
B-14 HOW REGULATORY CHANGES DRIVE INNOVATION IN PLEATABLE FILTER MEDIA Olivier Huss Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 125-127, 2018. |
---|
![]() |
Preliminary study on abatement of volatile organic compounds (VOCs) in gas phase using microbubble-containing water Norikazu Namiki*1, Sho Okamoto*1, Tomoya Mizushima*1, Ryoichi Nakayama*1, Shoichi Shimose*2, Noriyuki Sasaki*2 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 128-131, 2018. |
---|
![]() |
Improvement in photocatalytic degradation of volatile organic compounds (VOCs) using TiO2-contaning droplets generated by ultrasonic atomization Miyu Kimura*1, Ryoichi Nakayama*1, Norikazu Namiki*1, Kazuhiko Sekiguchi*2, Naoki Kagi*3 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 132-135, 2018. |
---|
![]() |
Influence of experimental factors on trapping of gaseous pollutants into liquid phase by micro-bubbling Kazuhiko Sekiguchi*1, Toshihide Nishitani*1, Kenshi Sankoda*1, Fumio Yasui*2 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 136-138, 2018. |
---|
![]() |
Biphasic degradation of organic pollutants by the combined use of ultrasonication and UV irradiation Kazuhiko Sekiguchi*1, Yusei Ono*1, Kenshi Sankoda*1, Norikazu Namiki*2, Susumu Nii*3 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 139-142, 2018. |
---|
![]() |
Sonophotocatalytic degradation of VOC in water using visible light-driven photocatalyst Kazuhiko Sekiguchi, Yuka Takahashi, Kenshi Sankoda Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 143-145, 2018. |
---|
![]() |
Performance Improvement by Optimizing Internal Structure of Nanofiber Filter-media (Part 2) Youichi Ohmori*1, Takafumi Seto*1, Li Bao*2, Kazuya Yanagita*2 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 146-148, 2018. |
---|
![]() |
Suppression of re-entrainment of particles captured on medium-performance filter media by loading with atomized APA solution and evaluation of their particle collection performance Kazuma Yoshimura*1, Ryoichi Nakayama*1, Norikazu Namiki*1, Shunsuke Kobayashi*2, Hideo Kunitomo*2, Takeshi Ikeda*2 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 149-152, 2018. |
---|
![]() |
Characterization of particle collection by charged fibrous filters for suppression of UFP formation from laser printers and their optimization Wataru Karatsu*1, Ryoichi Nakayama*1, Norikazu Namiki*1, Yoshiro Muramoto*2, Hiroshi Tanaka*2 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 153-156, 2018. |
---|
![]() |
Evaluation of particle collection performance of filter media composed of nano-fiber layer and base support media Ryoichi Nakayama, Daiki Kiuchi, Norikazu Namiki Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 157-160, 2018. |
---|
![]() |
The performance evaluation of air curtain at the entrance of refrigerating warehouse : Part3 Syo Shiina, Hiroyuki Ohno, Ryo Nagatsuka, Mamoru Okamoto, Naoki Watanabe Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 161-164, 2018. |
---|
![]() |
Study on temperature stratified clean room air conditioning system using downflow and upflow Masanori Sasaki, Satoshi Uemura, Kanta Fukumori Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 165-168, 2018. |
---|
![]() |
A Study on Non-Isothermal Characteristics of the Coanda Effect Caused by Indoor Air Using CFD Simulations Tatsuhiro Nogami, Yoshihide Suwa Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 169-171, 2018. |
---|
![]() |
Design of Fluid Control Circuit Using Fluidic Devices Keita Nakamori, Yoshihide Suwa, Ayaka Furuta Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 172-174, 2018. |
---|
![]() |
The study of Methods for Salt Prevention Filter Performance Test (Part2). Hironori Ishii, Kanae Yamamoto Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 175-178, 2018. |
---|
![]() |
Synthesis of porous polymer fiber via electrospinning method Takashi Ogi*1, Hiroyuki Murata*1, Kikuo Okuyama*1, Li Bao*2, Makoto Kobayashi*2 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 179-180, 2018. |
---|
![]() |
A study on an evaluation method of filter media for prevention of sea salt damage by using ACM sensor Kota Utsugi, Takahiro Tomioka, Yasushi Nishibori, Hiroshi Tanaka Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 181-182, 2018. |
---|
![]() |
Improvement in filtration performance of glass fiber air filter media Masashi Sato, Junji Nemoto, Keishi Tanifuji, Shota Fukushima, Toshihiko Soyama Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 183-186, 2018. |
---|
![]() |
Examination of air conditioning system for office which separated latent heat and sensible heat Takeshi Ebine, Yosuke Takiguchi Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 187-190, 2018. |
---|
![]() |
Airborne particle collection ability in the Yukashita of highly airtight and highly heat-insulating house ventilated by the Yukashita air Hiroyuki Harada Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 191-194, 2018. |
---|
![]() |
Control of Air Quality and Thermal Environment Using Buoyancy in High-rise Building Souichiro Yukizane*1, Tsubasa Ozeki*1, Yoshihide Suwa*1, Naoki Kagi*2 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 195-197, 2018. |
---|
![]() |
Parametric study on the ventilation efficiency in the room applying socks duct system Tomohiro Nagai*1, Yuki Sasagawa*1, Yoshihide Suwa*1, Hajime Tamura*2, Misa Fujii*2 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 198-200, 2018. |
---|
![]() |
Grasp of Microbial Sterilization Characteristics Using Chlorine Dioxide Gas, Part 2 Hiroki Arakawa, Hideto Takahashi Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 201-204, 2018. |
---|
![]() |
In-situ test about the reduction effect of airborne particles by an air cleaner in a hospital consultation room U Yanagi*1, Haruhiko Ogawa*2, Masato Mizuno*3, Li Bao*4 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 205-207, 2018. |
---|
![]() |
Decontamination of Biosafety Cabinet with Ozone : Evaluation of Alternative methods to Formaldehyde Kazuya Hiramatsu, Miki Shinya, Raku Shu Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 208-211, 2018. |
---|
![]() |
Investigation of hydrogen peroxide gas generation under low humidity conditions using sodium percarbonate Kazuhiko Sekiguchi*1, Kota Chida*1, Kenshi Sankoda*1, Fumio Yasui*2 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 212-215, 2018. |
---|
![]() |
Studies on the actual conditions of the odor substance pollution in the building environments and its countermeasure techniques, Part 2 Yukihiro Fukuda*1, Yosuke Ishii*1, Toshiki Sakuma*1, Yasunori Narita*1, Atsuo Nozaki*2, Yoshimasa Sato*3, Shinichiro Sato*3, Koji Mitsugi*4 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 216-218, 2018. |
---|
![]() |
Studies on the actual conditions of the odor substance pollution in the building environments and its countermeasure techniques, Part 3 Yasunori Narita*1, Yukihiro Fukuda*1, Kikumi Yoshida*1, Atsuo Nozaki*2, Yoshimasa Sato*3, Shinichiro Sato*3, Koji Mitsugi*4 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 219-221, 2018. |
---|
![]() |
A Study on the Chemical Substances Emitted from Natural Paint Atsuo Nozaki*1, Hisato Nishina*2, Toshiki Sakuma*3 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 222-223, 2018. |
---|
![]() |
Abatement of particle and odor concentrations in smoking spaces by air flow control Norikazu Namiki*1, Seiga Katagiri*1, Ryoichi Nakayama*1, Naoki Kagi*2 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 224-227, 2018. |
---|
![]() |
Survey on odor environment and control in facilities for the elderly Hoon KIM, Michiko Bando, Motoya HAYASHI, Haruki OSAWA Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 228-231, 2018. |
---|
![]() |
Study on the Influence of Architectural Planning of Laboratory and Make-up Air System on Performance of Biological Safety Cabinet Yuki Chiba*1, Hideaki Tani*1, Takuya Sato*1, Taku Hidaka*1, Daijiro Sone*1, Kentaro Amano*1, Yuji Terajima*2, Hisashi Motegi*2, Masayuki Kubota*2 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 232-235, 2018. |
---|
![]() |
Design of operating room air conditioning system consisting of dual control systems Naofumi IMAIDA, Yoko YAMADA Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 236-237, 2018. |
---|
![]() |
Thermal and clean performance evaluations of the actual operating rooms using dual control air conditioning systems Yoko YAMADA, Naofumi IMAIDA, Tomoharu FUJITA, Kazuyuki TOMIOKA Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 238-239, 2018. |
---|
![]() |
The 35th air cleanliness and contamination control study meeting held guidance 山崎省二 Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 243-243, 2018. |
---|