Search by Journal

  • HOME 
  •  >  Search by Journal
  •  >  Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control

Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control

Volume , Issue suppl / 2024
English Article   Japanese Article
  • Please note that metadata of J-type articlesare generated by machine-translation and the original texts are written in Japanese.

Japanese Article 41st Air Purification and Contamination Control Research Conference Announcement
藤井修二
Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): (1)-(1), 2024.

Japanese Article A-1 Fundamental study on visualization method for air flow in cleanrooms by PIV method using submicrometer-sized particles
Norikazu Namiki*1, Zen Maeno*1, Ryoma Mochizuki*1, Tomokatsu Sato*2, Koya Baba*2
Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 1-4, 2024.

Japanese Article A-2 Implementation of an FFU control system to a cleanroom with FFU ceiling clean system
Kosuke KONDO, Takayuki SOMEYA, Gen TAKEUCHI, Hisashi HASEBE, Chisato KOSAKA, Masayuki KOMATSUBARA
Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 5-8, 2024.

Japanese Article A-3 A Study on On-Site Evaluation Methods for Airborne Pharmaceutical Compound Dust Concentration and Container Cleanability in Pharmaceutical Manufacturing Facilities
Isao Tanaka, Kengo Tomita, Keiichi Yano, Takashi Kurihara, Yukiko Ota, Mona Amano, Shinnosuke Yano, Takeshi Hamada, Yoshiaki Tobe
Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 9-12, 2024.

Japanese Article A-4 The positive effects of various additives on water-charged Melt-Blown filter media.
Manabu Tachibana, Naotaka Kimura, Satoru Kobori
Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 13-15, 2024.

Japanese Article A-5 A proposal of Leak Test Method for HEPA Filter Installed on Ceiling in a Clean Room (Part 2) - Study of Eyelid for Pollution Control -
Chitake KARAKI, Tomokatsu SATO, Daisuke SUGATA
Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 16-19, 2024.

Japanese Article A-6 Analysis of space cleaning effect using air conditioning air filters
Yoko Onishi*1, Yoshinari Sano*1, Takuji Ikeda*1, Aoba Kawai*2, Yuki Yamagishi*2, Noboru Takiguchi*2, Takafumi Seto*2
Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 20-22, 2024.

Japanese Article New re-emerging infection and COVID19 have just begun until now
忽那賢志
Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 23-27, 2024.

Japanese Article A-7 Characterization of particle collection by high-efficiency air filter media made of PTFE fiber layers with different layer structures at the simultaneous loading with two sorts of particle
Norikazu Namiki, Zen Maeno, Akira Sato
Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 28-31, 2024.

Japanese Article A-8 Suppression of re-entrainment of Japanese cedar pollens and their allergen particles captured on glass-fiber media for medium-performance filters by atomizing APA-solution
Norikazu Namiki*1, Zen Maeno*1, Nanami Kamada*1, Kouki Kobayashi*2, Tatsuo Morita*2
Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 32-35, 2024.

Japanese Article A-9 Investigation and performance evaluation of high-performance filter media without using organic fluoropolymer
Naoya Nishioka*1, Zen Maeno*1, Norikazu Namiki*1, Akira Kaneyoshi*2, Kazuho Taniguchi*2, Satoru Kobori*2
Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 36-39, 2024.

Japanese Article A-10 Regeneration of medium-performance filter media loaded with particles by dry and wet cleaning
Takaaki Nakazato, Zen Maeno, Norikazu Namiki
Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 40-43, 2024.

Japanese Article A-11 A study about the leak of HEPA filter - Comparison between theoretical and experimental penetration rate -
Taichi MUKAI, Naoya NISHIMURA
Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 44-46, 2024.

Japanese Article Fundamentals and Application of Organic Fiber - Sustainable fiber initiatives -
Yoshitaka Aranishi
Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 49-51, 2024.

Japanese Article B-1 Survey on the Correlation between SVOC Concentrations in House Dust and Residential Environment
Hoon KIM*1, Yohei INABA*1, Kanae BEKKI*1, Kenichi AZUMA*2, Motoya HAYASHI*3, Atsuko IKEDA*3, Yu AIT BAMAI*3, Naohide SHINOHARA*4
Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 52-55, 2024.

Japanese Article B-2 Effectiveness of air purifier for improving indoor air quality
Yuki Yamagishi*1, Takafumi Seto*1, Tomoya Tamadate*1, Kanta Fukumori*2, Masanori Sasaki*2, Shota Endo*2
Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 56-57, 2024.

Japanese Article B-3 A study on suspended particulate matter removal performance of air pollution countermeasure products for residential air supply vents
Atsuo Nozaki*1, Yusuke Ichijo*2, Kumiko Takahashi*3, Koichi Katono*3
Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 58-59, 2024.

Japanese Article B-4 Research on Safe Nebulizer Inhalation Therapy Using Clean Booth - Clinical Research -
Yuka Uchida*1, Haruhiko Ogawa*1, Isao Ninomiya*2, Masato Mizuno*2, Yoshio Otani*3
Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 60-63, 2024.

Japanese Article B-5 Study on Evaluation Method of Aerosol Transmission Control Effect Using Image Information
Katsuya Inoue, Hiroyuki Nakajima, Norio Shoda
Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 64-65, 2024.

Japanese Article B-6 Development of 100 nm and 300 nm Particle Size Standards
Keiji Takahata, Hiromu Sakurai
Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 66-67, 2024.

Japanese Article B-7 Studies on the hydrogen gas safe application (part1) Concept of safe application of hydrogen gas and measures on facilities
Yoshihide Suwa*1, Kenji Yonezawa*2, Yoshiyuki Ono*2, Hiroshi Hirata*2, Chisato Tambara*2, Yuichi Tabata*2, Hiroya Hagio*2
Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 68-70, 2024.

Japanese Article B-8 Studies on the hydrogen gas safe application (part2) Numerical simulation of high-pressure hydrogen gas leakage
Chisato Tambara*1, Yoshiyuki Ono*1, Yuichi Tabata*1, Yoshihide Suwa*2
Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 71-74, 2024.

Japanese Article B-9 Studies on the hydrogen gas safe application (part3) Blast countermeasures through hydrogen gas explosion experiments and computer simulations
Yoshiyuki ONO*1, Kenji YONEZAWA*1, Hiroshi HIRATA*1, Yuichi TABATA*1, Yoshihide SUWA*2
Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 75-78, 2024.

Japanese Article B-10 Studies on the hydrogen gas safe application (part4) Experiment and numerical simulation of high-pressure hydrogen tank rupture accident
Yuichi Tabata*1, Yoshiyuki Ono*1, Kenji Yonezawa*1, Hiroshi Hirata*1, Hiroya Hagio*1, Yoshihide Suwa*2
Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 79-82, 2024.

Japanese Article B-11 Studies on the hydrogen gas safe application (part5) High-speed collision simulation of flying object and steel wall due to high-pressure tank rupture
Hiroshi Hirata*1, Kenji Yonezawa*1, Yoshiyuki Ono*1, Yuichi Tabata*1, Hiroya Hagio*1, Yoshihide Suwa*2
Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 83-86, 2024.

Japanese Article C-1 Study of a complete heat pump outdoor air processing device compatible with latent heat sensible heat separation air conditioning system using indoor exhaust air as heat source air
Takeshi Ebine
Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 87-90, 2024.

Japanese Article C-2 Study on under-blowing displacement air conditioning type Clean Room
Manabu Kuriyama, Koh Yamashita, Toshiyuki Motomura, Ryoji Shimokawa, Shigeru Nishimura
Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 91-93, 2024.

Japanese Article C-3 Study on Particle Collection Efficiency and Energy Consumption of Air Conditioning Filters during Office Building Operation
Hideaki Tani*1, Kazuki Wada*1, Daisuke Kuboi*2, Toshitada Kakegawa*2, Shoko Arakawa*2, Hideki Nambu*2, Reika Hagiya*2
Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 94-96, 2024.

Japanese Article C-4 Calculation and operation of the Carbon Footprint of Product (CFP) for clean equipment.
Hayato Kawaguchi, Masazumi Seki, Naoki Ogawa, Shinya Hirasawa
Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 97-100, 2024.

Japanese Article C-5 Efficient driving methods based on the basic characteristics of electric vehicles
Shigeru Tanaka, Tomoko Hara
Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 101-104, 2024.

Japanese Article Maker presentation
日本空気清浄協会
Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 107-118, 2024.

Japanese Article The natural energy utilization study in a building, facilities and introduction of the nZEB performance inspection example
垂水弘夫
Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 123-134, 2024.

Japanese Article B-12 Decontamination of Biosafety cabinets with low-concentration hydrogen peroxide vapor and acetic acid gas.
Sana Kakehi, Hitoshi Nakatsuka, Yuichi Nakashima, Junko Fukuda
Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 135-138, 2024.

Japanese Article B-13 Development of a new Choline dioxide Decontamination Machine for Class II Biological Safety Cabinet Considering Rust prevention
Hironori Miyata1, Tomohiko Sato2, Takahiro Muta2, Kouichi Eto3, Hidetaka Matsui4
Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 139-142, 2024.

Japanese Article B-14 Evaluation of Microbial Decontamination Method for Biosafety Cabinet Using Chlorine Dioxide Gas
Hiroki Arakawa*1, Hideto Takahashi*1, Mingoo Park*2, Megumi Tanaka*2, Shinya Iwahori*2, Toshio Sakai*2
Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 143-146, 2024.

Japanese Article B-15 Evaluation of compact H2O2 decontamination equipment for BSC
Yosuke Otsuka, Mamoru Okamoto
Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 147-150, 2024.

Japanese Article B-16 Performance improvement of electrified kitchen exhaust foods by jet induction
Eizo Murakami, Hitoshi Kohno
Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 151-152, 2024.

Japanese Article B-17 Ozone decomposition technology at high airflow condition
Kei Sakamoto, Yu Majima, Issei Tsuji, Toshiya Nashida
Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 153-154, 2024.

Japanese Article B-18 Study on recycling technology using the heating desorption in physical adsorption materials such as active carbons (Part 6)
Yusuke Ichijo, Atsuo Nozaki
Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 155-157, 2024.

Japanese Article B-19 A new approach to decontaminating disinfect spaces using low-concentration hydrogen peroxide vapor and acetic acid gas.
Hitoshi Nakatsuka, Yuichi Nakashima, Sana Kakehi, Junko Fukuda, Michiko Teshima
Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 158-161, 2024.

Japanese Article B-20 A study of bio-decontamination of air filters using vaporized peracetic acid (Part 3)
Makoto Shigeta, Takahiro Fujimori, Riko Yukawa, Yoko Onishi, Yoshinari Sano, Takuji Ikeda
Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 162-163, 2024.

Japanese Article B-21 Ecological distribution of the air-borne fungus Mycelia
Kosuke Takatori*1, Toru Shimizu*1, Minako Takatori*1, Atsuko Takahashi*1, Kanako Muramatsu*1, Susumu Shimizu*2
Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 164-167, 2024.

Japanese Article B-22 Bacterial flora in operating room during endoscopic surgery and thoracotomy
Yanagi U
Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 168-170, 2024.

Japanese Article B-23 Sterilization of the evaporative humidifier using the plasma treated water.
Tomokatsu SATO*1, Kazunori TAKASHIMA*2, Akira MIZUNO*2
Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 171-173, 2024.

Japanese Article C-6 Numerical analysis of local smoke isolation in smoking room where persons to smoke different sorts of cigarette coexist by airflow control using air curtain poles
Norikazu Namiki, Zen Maeno, Taishi Okawada
Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 174-177, 2024.

Japanese Article C-7 Behavior analysis of droplets and residue particles atomized from spray nozzles for spray cooling in greenhouses for horticulture and their measures
Norikazu Namiki*1, Moeka Takedomi*1, Zen Maeno*1, Masashi Wada*2, Mami Oishi*2
Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 178-181, 2024.

Japanese Article C-8 Drying behavior of droplets sprayed from high hardness of water containing soluble silicates and their countermeasures
Makoto Yamada, Zen Maeno, Norikazu Namiki
Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 182-185, 2024.

Japanese Article C-9 Photocatalytic degradation of volatile organic compounds (VOCs) using ultrasonically-generated droplets containing TiO2 particles combined with AOP (advanced oxidation process)
Takehiro Saito*1, Zen Maeno*1, Norikazu Namiki*1, Kazuhiko Sekiguchi*2, Naoki Kagi*3
Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 186-189, 2024.

Japanese Article C-10 A study about Development of Multiple CO2 meter and Relativity between Computer Fluid Dynamics - Part 3 ; Effect of Airflow by running trains -
Naoya NISHIMURA, Yasuhiro MINAMI
Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 190-192, 2024.

Japanese Article C-11 Derivation of 3D flow field from 2D flow data in multiple cross sections (3)
Yoshihide SUWA*1, Aiman MUHAMMAD*1, Jun Machii*2, Kenich Nakamura*2, Masashi Yasuki*2
Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 193-195, 2024.

Japanese Article C-12 Development of air volume monitoring system for natural ventilation equipment
Ryuto Yoshida*1, Tomohiro Yoshida*1, Muhammad Aiman bin Mohd Nor*1, Yoshihide Suwa*1, Kiyokazu Hosokawa*2, Hiroyuki Ueno*3, Daisaku Iga*3, Fukiko Obara*3, Fuyo Sakamaki*3, Kenichi Iriuchijima*3
Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 196-198, 2024.

Japanese Article C-13 Effects of Mechanical Ventilation System Differences in Housing on Volatile Organic Compound Concentrations
Sangin Park*1, Naoki Kagi*1, Wataru Umishio*1, Naohide Shinohara*2, Hoon Kim*3
Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 199-201, 2024.

Japanese Article C-14 Contaminant generation characteristics of craft spray products
Mayu Nagano, Naoki Kagi, Wataru Umishio
Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 202-204, 2024.

Japanese Article C-15 A study on the air exchange characteristics through a single opening
Seiya Kimura, Takemi Kabumoto, Muhammad Aiman, Yoshihide Suwa
Proceedings of Annual Technical Meeting on Air Cleaning and Contamination Control (suppl): 205-207, 2024.