Search by Journal
- HOME
- > Search by Journal
- > Japanese Journal of Clinical Laboratory Automation
Japanese Journal of Clinical Laboratory Automation
Volume , Issue suppl-1 / 1973


- Please note that metadata of J-type articlesare generated by machine-translation and the original texts are written in Japanese.
![]() |
The platelet measurement by Coulter Thrombocounter 川原浩二, 武市美智子, 小野益伸, 隅田秀文, 川井一男 Japanese Journal of Clinical Laboratory Automation (suppl-1): 5-7, 1973. |
---|
![]() |
Basic study of the serum Triglyceride autoanalysis method by Lipoproteine Lipase 高橋十郎, 林長蔵 Japanese Journal of Clinical Laboratory Automation (suppl-1): 8-11, 1973. |
---|
![]() |
Application to automatic analytical procedure and laboratory study of serum free sugar 荒井良雄, 池辺正, 佐々木禎一 Japanese Journal of Clinical Laboratory Automation (suppl-1): 12-14, 1973. |
---|
![]() |
About the introduction to development and the discrete-style automation studies analyzer of the new O-TB reagent for the blood sugar fixed-quantity to develop by 37 degrees Celsius warming 高原喜八郎*, 那須俊一*, 三上勲*, 鳥田美恵子*, 今村圭子*, 山田博**, 長屋美奈子** Japanese Journal of Clinical Laboratory Automation (suppl-1): 15-18, 1973. |
---|
![]() |
Basic examination of the S-GOT,S-GPT activity measurement by PYE UNICAM AC system Takeshi Sato, Naomi Okuda, Hisashi Kondo, Fumio Honda Japanese Journal of Clinical Laboratory Automation (suppl-1): 19-21, 1973. |
---|
![]() |
Use experience - GOT, GPT - of the reagent for the Fujisawa autoanalysis Fukiko Yamanaka, 小林紀崇, Kiyoshi Okuda Japanese Journal of Clinical Laboratory Automation (suppl-1): 22-25, 1973. |
---|
![]() |
Examination of the thymol, Kunkel reagents according (Fujisawa) to UNICAM system 岩元栄一, 杉町定, 西脇名賀子, 清瀬安代, 中西真澄 Japanese Journal of Clinical Laboratory Automation (suppl-1): 26-28, 1973. |
---|
![]() |
Application to PYE UNICAM AC 60 system of the ALP "Fujisawa" reagent kit Wataru Mizuta, Katsuhiro Fukuda Japanese Journal of Clinical Laboratory Automation (suppl-1): 29-31, 1973. |
---|
![]() |
Serum transaminase activity measurement with the automatic love autoanalyzer 飯居康弘 Japanese Journal of Clinical Laboratory Automation (suppl-1): 32-32, 1973. |
---|
![]() |
Use of automatic love experience in the middle scale hospital 光永弘 Japanese Journal of Clinical Laboratory Automation (suppl-1): 33-34, 1973. |
---|
![]() |
Use experience of the autoanalyzer automatic love 内田憲一 Japanese Journal of Clinical Laboratory Automation (suppl-1): 35-36, 1973. |
---|
![]() |
Use experience of the automatic love 斎藤功 Japanese Journal of Clinical Laboratory Automation (suppl-1): 37-39, 1973. |
---|
![]() |
The use situation of the automatic love in our hospital 三浦惇, 千葉勇治 Japanese Journal of Clinical Laboratory Automation (suppl-1): 40-42, 1973. |
---|
![]() |
Comparison of the measurements for a healthy subject by SMA 12/60 and the geek 金子康男*, 小田切敬子**, 津田安規子**, 相原ひろみ**, 小林純子**, 寺岡弘平**, 竹内稔**, 西淳*** Japanese Journal of Clinical Laboratory Automation (suppl-1): 43-45, 1973. |
---|
![]() |
Knowledge of SMA12/60 正路喜代美, 茂手木皓喜 Japanese Journal of Clinical Laboratory Automation (suppl-1): 46-48, 1973. |
---|
![]() |
About the change of styles on the occasion of the use of SMA12/60 Yoichi Miyahara, Toshiaki Usui Japanese Journal of Clinical Laboratory Automation (suppl-1): 49-52, 1973. |
---|
![]() |
About data handling of SMA12/60 trial - of -2 folds of record methods and microfilm 臼井敏明, 宮原洋一 Japanese Journal of Clinical Laboratory Automation (suppl-1): 53-55, 1973. |
---|
![]() |
Model - of the Laboratory Automation - laboratory automation in the medical supplies development Masahiro Seki, Hiroshi Nikaido husband, Kitaoka Shusuke Japanese Journal of Clinical Laboratory Automation (suppl-1): 56-58, 1973. |
---|
![]() |
Data processing of the spectrophotometer by RIC-8 using microcomputer Kiyoshi Suzuki eight, Yoichi Kaneko, Toshio Nohara Japanese Journal of Clinical Laboratory Automation (suppl-1): 59-61, 1973. |
---|
![]() |
About (patients = specimen) confirmation device "ID Reader Model 240 JOOKOO" - system and features for the biochemistry autoanalyzer - 松田武英, 村上忠司 Japanese Journal of Clinical Laboratory Automation (suppl-1): 62-63, 1973. |
---|
![]() |
Point to keep in mind - in laboratory study automation system - systems architecture using the minicomputer 小林紘 Japanese Journal of Clinical Laboratory Automation (suppl-1): 64-65, 1973. |
---|
![]() |
Trial manufacture of the curve vernier for the autoanalysis Haruo Hayashi *, Kengo Sudo **, Yasushi Nomura **, Akira Kawahara ** Japanese Journal of Clinical Laboratory Automation (suppl-1): 66-67, 1973. |
---|
![]() |
About data processing of Hycel Mark X due to minicomputer NEAC M4 Hiroshi Yokoyama, The Furuya right, Masumi Hosaka, Kazuko Sano Japanese Journal of Clinical Laboratory Automation (suppl-1): 68-70, 1973. |
---|
![]() |
About setting of the normal in the automatic screening Yasuo Kaneko *, Keiko Odagiri **, Yasunori Tsuda child **, Hiromi Aihara **, Junko Kobayashi **, Hiroshi Teraoka flat **, Minoru Takeuchi **, Sunao Nishi ***, Hiroshi Nakano *** Japanese Journal of Clinical Laboratory Automation (suppl-1): 71-71, 1973. |
---|
![]() |
Results management by the mean according to the day 住田修, 鷲野正治, 西口あい子, 古川信子 Japanese Journal of Clinical Laboratory Automation (suppl-1): 72-74, 1973. |
---|
![]() |
Study on data processing of the clinical chemistry analysis with the minicomputer Tortoise field Yasuro, Masahiko Mukai, Shigeaki Baba Japanese Journal of Clinical Laboratory Automation (suppl-1): 75-77, 1973. |
---|
![]() |
Investment project and benefit management about the laboratory study automation 坪武 Japanese Journal of Clinical Laboratory Automation (suppl-1): 78-82, 1973. |
---|
![]() |
Use experience of メコラブ E and C 片上伴子, 秋山佐代子, 小林紀崇, 奥田清 Japanese Journal of Clinical Laboratory Automation (suppl-1): 83-84, 1973. |
---|
![]() |
Use experience of the autoanalyzer (robot chemist) 関薩男, 肥後憲一郎, 田中寿一, 辻正一, 関正己 Japanese Journal of Clinical Laboratory Automation (suppl-1): 85-87, 1973. |
---|
![]() |
Use knowledge of the autoanalyzer robot chemist 栗山隆信*, 小野田勇*, 正路喜代美**, 茂手木皓喜** Japanese Journal of Clinical Laboratory Automation (suppl-1): 88-92, 1973. |
---|
![]() |
Use experience of LAC-060-00 小林純子*, 相原ひろみ*, 津田安規子*, 小田切敬子*, 竹内稔*, 寺岡弘平*, 高良毅**, 白石孝*** Japanese Journal of Clinical Laboratory Automation (suppl-1): 93-97, 1973. |
---|
![]() |
About a data processing system of LAC-060-00 (autoanalyzer) Fumio Watanabe Japanese Journal of Clinical Laboratory Automation (suppl-1): 98-99, 1973. |
---|
![]() |
Summary of Hitachi autoanalyzer M400 and the M500 mechanism 田中寿子, 森田寛二, 奥田清 Japanese Journal of Clinical Laboratory Automation (suppl-1): 100-101, 1973. |
---|
![]() |
Basic study of Hitachi clinical chemistry analyzer M500 Toshiko Nasu, Kanji Morita, Kiyoshi Okuda Japanese Journal of Clinical Laboratory Automation (suppl-1): 102-104, 1973. |
---|
![]() |
Examination about the GOT standard curve revision in Hitachi autoanalyzer M500 森田寛二, 奥田清 Japanese Journal of Clinical Laboratory Automation (suppl-1): 105-107, 1973. |
---|
![]() |
Trial of the U.V. assay of the transaminase by Hitachi M400 三橋文子, 和田佳子, 植本和子, 仁井谷久暢 Japanese Journal of Clinical Laboratory Automation (suppl-1): 108-109, 1973. |
---|
![]() |
About the clinical chemical testing with the Hitachi M400 autoanalysis machine normal - of - liver function test 曽山浩吉, 曽根淳, 大川原弘子, 福井巌 Japanese Journal of Clinical Laboratory Automation (suppl-1): 110-110, 1973. |
---|
![]() |
Of the systematization of the biochemistry analysis, actually Asako Matsui *, Akira Nakamura *, Reticulum Etsuko *, Minoru Yakata *, Hiroshi Inomata ** Japanese Journal of Clinical Laboratory Automation (suppl-1): 111-112, 1973. |
---|
![]() |
The operation situation of Vickers M300 清瀬濶, 中甫, 黒沢侑子, 太田技徳, 鄭梅珠, 水口清美 Japanese Journal of Clinical Laboratory Automation (suppl-1): 113-116, 1973. |
---|
![]() |
Trial of the standard procedure on the use of Vickers M-300 清瀬濶, 中甫, 黒沢侑子, 太田抜徳, 鄭梅珠, 水口清美 Japanese Journal of Clinical Laboratory Automation (suppl-1): 117-119, 1973. |
---|
![]() |
It is examination to becoming it eight items routine using Beckman DSA-560 two and Mini-Com.Scc-100 松尾弘明*, 菅原和行*, 高橋芳郎**, 幸田勝実** Japanese Journal of Clinical Laboratory Automation (suppl-1): 120-124, 1973. |
---|
![]() |
Serum total protein by Beckman DSA-560 and albumin assay (the usefulness and limit) 水野映二*, 林泰子*, 正岡一敏*, 仁科甫啓*, 北村元仕*, 竹内正樹** Japanese Journal of Clinical Laboratory Automation (suppl-1): 125-128, 1973. |
---|
![]() |
Uric acid measurement using the uricase catalase method by Beckman Instruments DSA560 加藤泰子, 古川信子, 山本達郎 Japanese Journal of Clinical Laboratory Automation (suppl-1): 129-131, 1973. |
---|
![]() |
Examination of the transaminase measurement (the UV method) by DSA560 池田清子, 徳其莫格, 木本啓子, 井川幸雄 Japanese Journal of Clinical Laboratory Automation (suppl-1): 132-133, 1973. |
---|
![]() |
Application to the amylase measurement of the Beckman DSA-560 autoanalyzer 中井一夫, 杉町葉子, 吉田一枝, 常峰芳美, 井原素子 Japanese Journal of Clinical Laboratory Automation (suppl-1): 134-136, 1973. |
---|
![]() |
DSA-560 About serum amylase byand γ one GTP measurement 富浦茂基, 竹久元彬, 八島弘昌 Japanese Journal of Clinical Laboratory Automation (suppl-1): 137-141, 1973. |
---|
![]() |
Autoanalysis of the enzyme activity initial rate by enzyme reaction rate analyzer "ERA-1" Yoshimasa Kuga, Kazue Oyama, Kiyoshi Suzuki eight Japanese Journal of Clinical Laboratory Automation (suppl-1): 142-144, 1973. |
---|
![]() |
ENZYMAT (UK Joyce-Loebl & Company Ltd) Fundamental study of enzyme activity automatic measuring device 吉田信雄, 奥田拓治 Japanese Journal of Clinical Laboratory Automation (suppl-1): 145-147, 1973. |
---|
![]() |
Examination of the measurement of the Lipase activity by Reaction rate analyzer Noriko Tsujimoto, Mieko Oyabu, Iwao Oshiro, Jiro Maeda Japanese Journal of Clinical Laboratory Automation (suppl-1): 148-150, 1973. |
---|
![]() |
Examination about serum CPK by LKB8600 reaction rate analyzer and the Triglyceride measurement 田島久仁美, 石井暢 Japanese Journal of Clinical Laboratory Automation (suppl-1): 151-153, 1973. |
---|
![]() |
Application to autoanalysis of the amylase activity measurement by the chromogenic method 森田寛二, 奥田清 Japanese Journal of Clinical Laboratory Automation (suppl-1): 154-157, 1973. |
---|
![]() |
52. Ultraviolet rate assay of Al-P which assumes α-Naphthyl Phosphate a substrate 溝口香代子, 菅野剛史 Japanese Journal of Clinical Laboratory Automation (suppl-1): 158-159, 1973. |
---|
![]() |
It is had experience with an application the EDPS to laboratory tests Akira Fukuda Japanese Journal of Clinical Laboratory Automation (suppl-1): 160-162, 1973. |
---|
![]() |
Induction - experience and problems - of the computer to laboratory tests Shigeaki Baba *, Tortoise field Yasuro *, Masaaki Kashima **, Shozo Omori **, Takeo Kasai ***, 塩尻孝正 ***, Tetsuo Yoshida *** Japanese Journal of Clinical Laboratory Automation (suppl-1): 163-164, 1973. |
---|
![]() |
Present conditions and future direction - of autoanalysis and data processing system - Tokushima University hospital central laboratory in the clinical biochemistry laboratory 大島一洋*, 小林紘** Japanese Journal of Clinical Laboratory Automation (suppl-1): 165-167, 1973. |
---|
![]() |
Induction of the computer to laboratory tests Junji Shimada Japanese Journal of Clinical Laboratory Automation (suppl-1): 168-170, 1973. |
---|
![]() |
Introduction - experience and problems - of the computer to laboratory tests 菅沼源二, 松岡茂 Japanese Journal of Clinical Laboratory Automation (suppl-1): 171-172, 1973. |
---|
![]() |
Problems in the enzyme activity measurement Hiroshi Wada Japanese Journal of Clinical Laboratory Automation (suppl-1): 173-174, 1973. |
---|
![]() |
The measurement of the enzyme activity by the Discrete method 清瀬濶, 中甫 Japanese Journal of Clinical Laboratory Automation (suppl-1): 175-179, 1973. |
---|
![]() |
About the new trial -1 reaction system two enzyme measurement to Multiple Enzyme Analysis - 菅野剛史, 溝口香代子, 竹下栄子 Japanese Journal of Clinical Laboratory Automation (suppl-1): 180-183, 1973. |
---|
![]() |
Enzymatic reaction speed autoanalyzer 奥田清, 小林紀崇 Japanese Journal of Clinical Laboratory Automation (suppl-1): 184-187, 1973. |
---|