Search by Journal
- HOME
- > Search by Journal
- > Journal of Japanese Society for Replacement Arthroplasty
Journal of Japanese Society for Replacement Arthroplasty
Volume 32, Issue / 2002
![](/en/img/e.gif)
![](/en/img/j.gif)
- Please note that metadata of J-type articlesare generated by machine-translation and the original texts are written in Japanese.
![]() |
Ten years results of the acetabulum side reimplantation using the allogeneic bone 塚本正美, 浅井富明, 近藤健治, 金子敦史, 奥澤継雄, 櫻井智浩, 岩附英史 Journal of Japanese Society for Replacement Arthroplasty 32: 1-2, 2002. |
---|
![]() |
Acetabular roof reconstruction by the Impaction Bone Graft method 片山直行, 鈴木孝治, 三浪三千男, 松野誠夫 Journal of Japanese Society for Replacement Arthroplasty 32: 3-4, 2002. |
---|
![]() |
Results of the acetabular roof reconstruction using the Kerboull cross plate 横山隆文, 熊沢やすし, 三井博正 Journal of Japanese Society for Replacement Arthroplasty 32: 5-6, 2002. |
---|
![]() |
Kerboull cross, experience of the acetabular roof rebuilding with the KT plate 西村立也, 澤口毅, 井村弥寿子 Journal of Japanese Society for Replacement Arthroplasty 32: 7-8, 2002. |
---|
![]() |
Results of KEL Bour cross plate in our hospital and the KT plate 石井政次*, 大楽勝之*, 浜崎允*, 高木理彰**, 小林真司**, 山川正紀**, 佐藤哲也**, 川路博之**, 新田長生**, 井田英雄*** Journal of Japanese Society for Replacement Arthroplasty 32: 9-10, 2002. |
---|
![]() |
The bipolar type artificial head replacement for the avascular necrosis femoral head symptom: Hip joint mirror views and short-term results 末永英慈, 野口康男, 神宮司誠也, 首藤敏秀, 中島康晴, 山本卓明, 岩本幸英 Journal of Japanese Society for Replacement Arthroplasty 32: 11-12, 2002. |
---|
![]() |
About the change over time of the image of X-rays of the Bipolar type artificial head replacement for the avascular necrosis femoral head symptom 原田真一, 榎本寛, 岡野邦彦, 稲冨健司郎, 進藤裕幸 Journal of Japanese Society for Replacement Arthroplasty 32: 13-14, 2002. |
---|
![]() |
It is results of the bipolar type artificial head replacement passed more than ten years after the operation for an avascular necrosis femoral head symptom 長谷川正裕, 須藤啓広, 内田淳正 Journal of Japanese Society for Replacement Arthroplasty 32: 15-16, 2002. |
---|
![]() |
Long-term results on the acetabulum side of the Harris Galante total hip replacement 加藤文雄, 冬賀秀一, 柴伸昌, 西原洋彦 Journal of Japanese Society for Replacement Arthroplasty 32: 17-18, 2002. |
---|
![]() |
A concept of the Lubeck type total hip prosthesis (socket) and clinical results 増原建作 Journal of Japanese Society for Replacement Arthroplasty 32: 19-20, 2002. |
---|
![]() |
Long-term results of Lord-type Porous Coated Long Stem 一青勝雄*, 丸山祐一郎*, 原章*, 太田義人*, 佐久間吉雄*, 横山実*, 金澤博明*, 久保田光昭*, 真田玲子*, 野沢雅彦**, 前澤克彦**, 黒澤尚**, 宮崎弘*** Journal of Japanese Society for Replacement Arthroplasty 32: 21-22, 2002. |
---|
![]() |
Use experience of the Osteonics THA in our hospital 福田寛二, 辻本晴俊, 福岡宏, 赤木将男, 浜西千秋 Journal of Japanese Society for Replacement Arthroplasty 32: 23-24, 2002. |
---|
![]() |
Of the PerFix HA cementless total hip prosthesis primarily about short-term results - hydroxyapatite coat on the thighbone side and the surface coarseness - 神宮司誠也, 中島康晴, 武田真幸, 野口康男, 首藤敏秀, 山本卓明, 岩本幸英 Journal of Japanese Society for Replacement Arthroplasty 32: 25-26, 2002. |
---|
![]() |
Ten years results of the cementless Lubeck total hip prosthesis 西塔進*, 渋谷高明**, 福田和也**, 太田信彦**, 裏岡富次**, 青木克**, 平尾眞**, 森本大樹** Journal of Japanese Society for Replacement Arthroplasty 32: 27-28, 2002. |
---|
![]() |
Triangular distal centralizer and distal cement mantle in cemented total hip arthroplasty 川手健次*1, 大村哲司*1, 玉井克弥*1, 高倉義典*1, 日吉信之*2, 寺西朋裕*3, 横井一之*4 Journal of Japanese Society for Replacement Arthroplasty 32: 29-30, 2002. |
---|
![]() |
Short-term results of the stem in the cementless PCA-E type THA 三上浩*, 岡田祐司*, 米津浩*, 田村竜也*, 水谷滋**, 岩瀬毅信**, 杉峰雅彦**, 正木國弘***, 森本訓明*** Journal of Japanese Society for Replacement Arthroplasty 32: 31-32, 2002. |
---|
![]() |
Short-term results of Spongiosa Metal II 森本大樹*, 太田信彦*, 井本一彦*, 福田和也*, 渋谷高明*, 裏岡富市*, 平尾眞*, 青木克*, 西塔進** Journal of Japanese Society for Replacement Arthroplasty 32: 33-34, 2002. |
---|
![]() |
It is results after the operation of the cementless total hip prosthesis 山本謙吾*, 今給黎篤弘*, 松浦清人*, 正岡利紀*, 小泉隆司*, 間中昌和*, 木村大*, 反町武史*, 伊藤康二**, 佐野圭二**, 布田大介** Journal of Japanese Society for Replacement Arthroplasty 32: 35-36, 2002. |
---|
![]() |
Examination - of the long-term results - thigh side X-rays change out of one of AML type cementless total hip replacement for the Osteoarthritis of the hip 吉原愛雄*, 逸見治*, 森田充浩*, 川路幸仁*, 冨士川恭輔*, 山田治基** Journal of Japanese Society for Replacement Arthroplasty 32: 37-38, 2002. |
---|
![]() |
It is the results of 10-14 years after the PCA cementless total hip prosthesis technique 河村春生*, Robert B. Bourne**, Michael J. Dunbar**, Cecil H. Rorabeck** Journal of Japanese Society for Replacement Arthroplasty 32: 39-40, 2002. |
---|
![]() |
Movement of mobile bearing in the LCS total knee prosthesis plastic surgery 八木知徳 Journal of Japanese Society for Replacement Arthroplasty 32: 41-42, 2002. |
---|
![]() |
Tibial relative rotation alignment evaluation at deep flexure of the TKA patients 藤井二郎*, 黒瀬靖郎*, 山本隆博**, 丹羽滋郎*** Journal of Japanese Society for Replacement Arthroplasty 32: 43-44, 2002. |
---|
![]() |
Short-term results of the total knee prosthesis single condyle replacement 八木知徳 Journal of Japanese Society for Replacement Arthroplasty 32: 45-46, 2002. |
---|
![]() |
New approach - second report to cementless ceramic total knee prosthesis 野田岩男, 増田真吾, 北野宏幸, 池田潤二, 吉原雄祐, 向健, 下唐湊俊彦 Journal of Japanese Society for Replacement Arthroplasty 32: 47-48, 2002. |
---|
![]() |
The measurement of urinary deoxypyridinoline (DPD) before and after the operation of the Total Knee Arthroplasty patients 柳下和慶, 宗田大, 池田浩夫, 四宮謙一 Journal of Japanese Society for Replacement Arthroplasty 32: 49-50, 2002. |
---|
![]() |
About the angle of torsion of examination (the third report) - thighbone using the MRI image for the design of the total knee prosthesis - 澤村千草, 宗田大, 池田浩夫, 柳下和慶, 四宮謙一 Journal of Japanese Society for Replacement Arthroplasty 32: 51-52, 2002. |
---|
![]() |
Reliability of the tibia nodule as the anatomical index to determine rotation alignment in the Total Knee Arthroplasty 山田邦雄, 今泉司, 高田直也, 金嘉朗, 河村文徳, 住田篤紀, 嶋田航也, 草部拓馬, 山上貴也 Journal of Japanese Society for Replacement Arthroplasty 32: 53-54, 2002. |
---|
![]() |
Association between use of bone cement and vital prognosis for the elderly people artificial head replacement 市村和徳 Journal of Japanese Society for Replacement Arthroplasty 32: 55-56, 2002. |
---|
![]() |
Long-term results out of one of Bipolar type artificial head replacement for the thighbone neck inside bone fracture 間中昌和, 山本謙吾, 正岡利紀, 小野彰夫, 今給黎篤弘 Journal of Japanese Society for Replacement Arthroplasty 32: 57-58, 2002. |
---|
![]() |
Radiographic examination of the bipolar artificial head replacement long-term course case for the Osteoarthritis of the hip 藤田貴也*, 柳本繁*, 本間隆之*, 伊藤大助*, 坂巻豊教** Journal of Japanese Society for Replacement Arthroplasty 32: 59-60, 2002. |
---|
![]() |
Results of the Bipolar type total hip replacement for the Osteoarthritis of the hip 福田寛二, 辻本晴俊, 福岡宏, 赤木将男, 浜西千秋 Journal of Japanese Society for Replacement Arthroplasty 32: 61-62, 2002. |
---|
![]() |
It is results after the operation of the THA for the rapid destruction type coxarthropathy 多田昌弘*, 鍵山博士*, 岩城啓好*, 西塔進*, 辺見茂** Journal of Japanese Society for Replacement Arthroplasty 32: 63-64, 2002. |
---|
![]() |
Results of the cementless socket in the mortar bottom implantation type THA 小川原雅隆, 杉森端三, 西野暢, 兼氏歩, 松本忠美 Journal of Japanese Society for Replacement Arthroplasty 32: 65-66, 2002. |
---|
![]() |
Thighbone stem - BINARFIX Stem - medium-term results (more than five years the course case) that we combined cementless fixation with cement fixation 長谷川功 Journal of Japanese Society for Replacement Arthroplasty 32: 67-68, 2002. |
---|
![]() |
Surgical process of the Total Hip Arthroplasty bilateral simultaneous enforcement case 田村治郎*, 川那辺圭一*, 清水基行*, 田中健二*, 松崎尚志*, 中村孝志*, 飯田寛和** Journal of Japanese Society for Replacement Arthroplasty 32: 69-70, 2002. |
---|
![]() |
An abrasion form and abrasion mechanism of the polyethylene cup slide aspect 正岡利紀*, 山本謙吾*, 宍戸孝明*, 溝上達朗*, 今給黎篤弘*, Ian C. Clarke**, 東海林宏**, 田村治郎** Journal of Japanese Society for Replacement Arthroplasty 32: 71-72, 2002. |
---|
![]() |
Examination about the volume abrasion counting in the total hip prosthesis acetabular roof cup 溝上達朗*, 正岡利紀*, 宍戸孝明*, 山本謙吾*, 今給黎篤弘*, 赤木将男**, 東海林宏**, Ian C. Clarke** Journal of Japanese Society for Replacement Arthroplasty 32: 73-74, 2002. |
---|
![]() |
Product precision of the total hip prosthesis 松原正明, 鈴木康司, 神野哲也, 麻生義則, 宗田大, 四宮謙一 Journal of Japanese Society for Replacement Arthroplasty 32: 75-76, 2002. |
---|
![]() |
The effect that 'Lift-off' motion gives to UHMWPE 戸堂慎一 Journal of Japanese Society for Replacement Arthroplasty 32: 77-78, 2002. |
---|
![]() |
- by the use of reconstruction - person mechanic ligament for the patellar ligament tear after the Total Knee Arthroplasty 吉本栄治, 王寺享弘, 徳永真巳, 宏洲士郎 Journal of Japanese Society for Replacement Arthroplasty 32: 79-80, 2002. |
---|
![]() |
Use experience of the Total Knee Arthroplasty for posttraumatic Stiff knee 中村立一, 北岡克彦, 羽柴謙作, 富田勝郎 Journal of Japanese Society for Replacement Arthroplasty 32: 81-82, 2002. |
---|
![]() |
One case that caused the damage of the tibia plate after the Total Knee Arthroplasty early 木全則文, 宮本浩秀, 川島正幹, 佐藤啓二 Journal of Japanese Society for Replacement Arthroplasty 32: 83-84, 2002. |
---|
![]() |
Compatibility evaluation of the thighbone component using the plan work station in front of ROBODOC art 西原俊作*, 菅野伸彦*, 西井孝*, 三木秀宣*, 萩尾佳介*, 岸田友紀*, 吉川秀樹*, 越智隆弘*, 中村宣雄**, 原口圭司**, 柿本明博** Journal of Japanese Society for Replacement Arthroplasty 32: 85-86, 2002. |
---|
![]() |
Protective efficacy of the pulmonary embolism in the THA technique with the surgery support robot 萩尾佳介*, 菅野伸彦*, 西井孝*, 三木秀宣*, 西原俊作*, 岸田友紀*, 吉川秀樹*, 越智隆弘*, 高階雅紀**, 中村宣雄*** Journal of Japanese Society for Replacement Arthroplasty 32: 87-88, 2002. |
---|
![]() |
Total hip replacement using ROBODOC(R) 廣瀬和義*, 高木英希*, 山内健一*, 岩田久** Journal of Japanese Society for Replacement Arthroplasty 32: 89-90, 2002. |
---|
![]() |
Three-dimensional exercise of Bi-Surface total knee prosthesis analysis 小池和広*, 岡正典*, 浅野太洋**, 中川泰彰**, 安田義**, 中村孝志**, 赤木将男*** Journal of Japanese Society for Replacement Arthroplasty 32: 91-92, 2002. |
---|
![]() |
Exercise analysis of the Mobile Bearing type TKR at knee flexure 熊谷優*, 大川孝浩*, 永田見生*, 水野泰之**, J. J. Elias***, I. Mitchell***, S. M. Mattessich***, E. Y. S. Chao*** Journal of Japanese Society for Replacement Arthroplasty 32: 93-94, 2002. |
---|
![]() |
After the Total Knee Arthroplasty kneel, and is analyzed movement using fluoroscope in the deep flexure by movement 金粕浩一*, 本荘茂*, 中田理也*, 加藤弘巳*, Banks SA** Journal of Japanese Society for Replacement Arthroplasty 32: 95-96, 2002. |
---|
![]() |
About rotation alignment of the thighbone component in the Total Knee Arthroplasty comparison between - dependent cut method and independent cut method - 白石浩一, 新井堅, 浜崎晶彦, 諸岡孝明, 友弘慎一, 田縁竜一, 城野修, 楊昌憲 Journal of Japanese Society for Replacement Arthroplasty 32: 97-98, 2002. |
---|
![]() |
Examination about the range of motion of the rear capsulectomy carried out at Total Knee Arthroplasty 金粕浩一, 本荘茂, 中田理也, 加藤弘巳 Journal of Japanese Society for Replacement Arthroplasty 32: 99-100, 2002. |
---|
![]() |
It is the association of results after the baseline tonus and the operation of the soft tissue in the Total Knee Arthroplasty 政田俊明*, 格谷義徳*, 山野慶樹*, 小林章朗** Journal of Japanese Society for Replacement Arthroplasty 32: 101-102, 2002. |
---|
![]() |
About invention of use experience - Soft tissue balancing of the Nexgen LPS-Flex type total knee prosthesis - 山田泰士*, 北岡克彦**, 羽柴謙作**, 山門浩太郎**, 中村立一** Journal of Japanese Society for Replacement Arthroplasty 32: 103-104, 2002. |
---|
![]() |
Treatment result of the Charnley-type total hip prosthesis by the initial surgical procedure for the acetabular dysplasia crotch 高柳聡*1, 田中宏志*1, 佐々木泰*1, 高岸憲二*1, 長田純一*2, 小林敏彦*3, 内川健*4 Journal of Japanese Society for Replacement Arthroplasty 32: 105-106, 2002. |
---|
![]() |
Results and concept of Charnley hip replacement using improved techniques - 10-18 year follow-up of Autron 90 - 野村隆洋 Journal of Japanese Society for Replacement Arthroplasty 32: 107-108, 2002. |
---|
![]() |
More than long-term results -10 year of Harris HD2 follow-up study - 池田寛*, 武石浩之*, 土方浩美**, 梅原新栄*** Journal of Japanese Society for Replacement Arthroplasty 32: 109-110, 2002. |
---|
![]() |
Results five years of the Precision total hip prosthesis or more 澤口毅, 増山茂, 西村立也, 森永敏生, 茂住宣弘, 原隆, 田中嘉雅 Journal of Japanese Society for Replacement Arthroplasty 32: 111-112, 2002. |
---|
![]() |
X-ray evaluations five years of the use of medullary cavity support type cement total hip prosthesis MX-1 stem or more 安田舜一*, 橋詰謙三*, 田中俊輔*, 角南義文**, 原靖隆** Journal of Japanese Society for Replacement Arthroplasty 32: 113-114, 2002. |
---|
![]() |
About possibility of the ceramic on ceramic THA using high tenacity materials 森田有亮*, 中田健一*, 吉田秀幸*, 池内健*, 新原皓一**, 関野徹**, 金允護** Journal of Japanese Society for Replacement Arthroplasty 32: 115-116, 2002. |
---|
![]() |
Examination of the aseptic loosening case of Metasul Wagner Standard Cup which occurred after the operation early 前沢克彦*, 野沢雅彦*, 森薫*, 榎本文世*, 黒澤尚*, 一青勝雄** Journal of Japanese Society for Replacement Arthroplasty 32: 117-118, 2002. |
---|
![]() |
Clinical results of the cementless THA using the AML type Duraloc type acetabular roof socket 名越智*, 高田潤一*, 桑原弘樹*, 岩崎智紀*, 須田祐之*, 渡部哲也*, 長尾正人*, 山下敏彦*, 久木田隆** Journal of Japanese Society for Replacement Arthroplasty 32: 119-120, 2002. |
---|
![]() |
About change over time on the acetabular roof side in the Hybrid THA 北川七也, 長谷川和寿, 飯田泰明, 奥秋保, 五十嵐昇, 勝呂徹 Journal of Japanese Society for Replacement Arthroplasty 32: 121-122, 2002. |
---|
![]() |
Invention of the surgical procedure of cementless cup (Shearer) with the rim 竹内啓, 安藤謙一, 中川雅人, 重盛香苗 Journal of Japanese Society for Replacement Arthroplasty 32: 123-124, 2002. |
---|
![]() |
Comparison - in the presence or absence of size alignment using the CT before radiographic examination - operation of the PerFixHA stem 大村哲司*, 川手健次*, 日吉信之*, 寺西朋裕*, 玉井克弥*, 高倉義典*, 片岡靖久** Journal of Japanese Society for Replacement Arthroplasty 32: 125-126, 2002. |
---|
![]() |
Clinical results of the cementless stem for elderly people 伊藤康二*, 佐野圭二*, 稲畠勇仁*, 大友通明*, 森下恭資*, 木村隆雄*, 山本謙吾**, 今給黎篤弘** Journal of Japanese Society for Replacement Arthroplasty 32: 127-128, 2002. |
---|
![]() |
Comparison between biological solidity and analysis - primary operation and reimplantation - of stress shielding in the distal fixed type cementless stem 高田潤一*, 名越智*, 長尾正人*, 桑原弘樹*, 小幡浩之*, 岩城智紀*, 山下敏彦*, 石井清一*, 久木田隆** Journal of Japanese Society for Replacement Arthroplasty 32: 129-130, 2002. |
---|
![]() |
Use experience of the S-ROM stem for the subluxation-related coxarthropathy after the thighbone abduction osteotomy 星野瑞, 宮下孝正, 友保洋三, 西法正 Journal of Japanese Society for Replacement Arthroplasty 32: 131-132, 2002. |
---|
![]() |
Mid-term results of Modular cementless stem 神戸太一, 内藤正俊, 秋吉祐一郎, 浅山勲 Journal of Japanese Society for Replacement Arthroplasty 32: 133-134, 2002. |
---|
![]() |
Using a plan system before results and -3 dimensions of custom base Off-the-shelf stems technique of custom stem six years with the lateral flare - 井口普敬*1, 田中信彦*2, 川西利行*2, 松井宣夫*2, 吉田行雄*3, 種田陽一*4 Journal of Japanese Society for Replacement Arthroplasty 32: 135-136, 2002. |
---|
![]() |
Examination of results short-term after the operation of Hi-tech Knee PS type 常泉吉一*1, 鈴木昌彦*1, 付岡正*1, 守屋秀繁*1, 李泰鉉*2, 金泰成*3, 玉井浩*4, Scott A. Banks*5, 蔵本孝一*6 Journal of Japanese Society for Replacement Arthroplasty 32: 137-138, 2002. |
---|
![]() |
It is results after the Hy-Flex II Total Knee Arthroplasty and the operation 永島正一, 山崎純司, 山本宗宏, 宮本洋介, 岩川賀世, 竹之内研二, 田中秀和, 吉野槇一 Journal of Japanese Society for Replacement Arthroplasty 32: 139-140, 2002. |
---|
![]() |
A design concept of Bisurface Knee and clinical results 赤木将男*1, 浜西千秋*1, 上尾豊二*2, 松末吉隆*3, 中村孝志*4 Journal of Japanese Society for Replacement Arthroplasty 32: 141-142, 2002. |
---|
![]() |
Comparison of ROM between OpteTrac and PFC total knee arthroplasty 大島和也*, 小林千益*, 斎藤直人*, 縄田昌司*, 堀内博志*, 太田浩史*, 高岡邦夫*, 吉村康夫** Journal of Japanese Society for Replacement Arthroplasty 32: 143-144, 2002. |
---|
![]() |
Comparison between mobile bearing and fixed bearing in bilateral total knee prosthesis cases 渡邉哲*, 菅本一臣*, 冨田哲也**, 橋本英雄**, 橋本淳**, 吉川秀樹**, 藤井昌一*** Journal of Japanese Society for Replacement Arthroplasty 32: 145-146, 2002. |
---|
![]() |
Patellar unsubstituted Total Knee Arthroplasty using Subvastus approach 六本木哲*, 富田泰次*, 大橋栄*, 金潤寿*, 林真仁*, 広瀬仁**, 杉山肇*** Journal of Japanese Society for Replacement Arthroplasty 32: 147-148, 2002. |
---|
![]() |
About deep flexure after short-term results - TKA of the NexGen-Legacy Posterior Stabilized - total knee prosthesis - 宮本浩秀, 川島正幹, 木全則文, 佐藤啓二 Journal of Japanese Society for Replacement Arthroplasty 32: 149-150, 2002. |
---|
![]() |
Long-term results - A 10-year minimum follow-up - of the PCA type Total Knee Arthroplasty 宮城哲, 王寺享弘, 吉本隆昌, 徳永純一, 小林晶 Journal of Japanese Society for Replacement Arthroplasty 32: 151-152, 2002. |
---|
![]() |
Total hip prosthesis reimplantation with the support ring 斎藤修, 龍順之助, 坂本雅光, 工藤太郎, 西郷嘉一郎, 石井隆雄 Journal of Japanese Society for Replacement Arthroplasty 32: 153-154, 2002. |
---|
![]() |
More than results -2 year of the artificial mortar reimplantation using support ring about the course case - 高平尚伸, 糸満盛憲, 東計, 内山勝文, 宮部基 Journal of Japanese Society for Replacement Arthroplasty 32: 155-156, 2002. |
---|
![]() |
Biomechanical concept about the cementless fixation of the thighbone component in total hip replacement, the reimplantation 大谷卓也, 藤井克之, 初海宏, 加藤努, 青柳充, 鈴木恵介 Journal of Japanese Society for Replacement Arthroplasty 32: 157-158, 2002. |
---|
![]() |
Results of the total hip prosthesis reimplantation using the bone cement non-use type fully porous stem 本間隆之*, 柳本繁*, 藤田貴也*, 伊藤大助*, 坂巻豊教** Journal of Japanese Society for Replacement Arthroplasty 32: 159-160, 2002. |
---|
![]() |
Use experience Acetabular Reconstruction with Burch-Schneider anti-protrusio cage of Wagner SL revision stem 川西利幸*, 小林正明*, 永谷祐子*, 松井宣夫*, 種田陽一**, 吉田行雄*** Journal of Japanese Society for Replacement Arthroplasty 32: 161-162, 2002. |
---|
![]() |
Invention of the appliance for Impaction Bone Grafting in the total hip prosthesis reimplantation 米田昌弘, 大橋弘嗣, 格谷義徳, 小林章郎, 山野慶樹 Journal of Japanese Society for Replacement Arthroplasty 32: 163-164, 2002. |
---|
![]() |
Effect to give to solidity of stem of the HA granule mixture in impaction graft at total hip prosthesis reimplantation 大橋弘嗣*, 小林章郎*, 格谷義徳*, 米田昌弘*, 山野慶樹*, 田辺裕治** Journal of Japanese Society for Replacement Arthroplasty 32: 165-166, 2002. |
---|
![]() |
Examination of the deep part infection case in the bipolar type artificial head replacement 森田光明, 西村典久, 元田忠伸, 國吉裕子 Journal of Japanese Society for Replacement Arthroplasty 32: 167-168, 2002. |
---|
![]() |
It is one patient of ceramic who had the deep part infection vs. the ceramic total hip prosthesis for damage of the ceramic inlay 山田邦雄, 今泉司, 高田直也, 金嘉朗, 河村文徳, 住田篤紀, 嶋田航也, 草部拓馬, 山上貴也 Journal of Japanese Society for Replacement Arthroplasty 32: 169-170, 2002. |
---|
![]() |
Results and problems of the tumor type artificial joint for bone soft part tumor 吉田行弘, 川野壽, 大幸俊三, 龍順之助 Journal of Japanese Society for Replacement Arthroplasty 32: 171-172, 2002. |
---|
![]() |
Short-term results of cementless cup to fix in Big lag screw 須藤啓広, 長谷川正裕, 内田淳正 Journal of Japanese Society for Replacement Arthroplasty 32: 173-174, 2002. |
---|
![]() |
Reimplantation (evaluation on the acetabular roof side) from bipolar type articular head prosthesis to all total hip prosthesis 柳本繁*, 本間隆之*, 藤田貴也*, 伊藤大助*, 吉田宏*, 坂巻豊教** Journal of Japanese Society for Replacement Arthroplasty 32: 175-176, 2002. |
---|
![]() |
Results and problems of the total hip prosthesis reimplantation 坂本央, 川村秀哉, 山口智太郎 Journal of Japanese Society for Replacement Arthroplasty 32: 177-178, 2002. |
---|
![]() |
Examination of the case given reimplantation using cement for use of cement Total Hip Arthroplasty 岡野邦彦, 榎本寛, 原田真一, 進藤裕幸 Journal of Japanese Society for Replacement Arthroplasty 32: 179-180, 2002. |
---|
![]() |
One case that ceramics inlay of the Ceramic-on-ceramic total hip prosthesis was damaged 長谷川正裕*, 須藤啓広*, 内田淳正*, 分部泉** Journal of Japanese Society for Replacement Arthroplasty 32: 181-182, 2002. |
---|
![]() |
Two cases that removed a cementless THA cup without the slack, and was given reimplantation 森島庸輔*, 山田治基*, 中野真一郎*, 山路哲生*, 寺田信樹*, 清水端松幸**, 逸見治***, 吉原愛雄***, 森田充治*** Journal of Japanese Society for Replacement Arthroplasty 32: 183-184, 2002. |
---|
![]() |
Early abrasion of Cemented Hylamer Cup 岩瀬敏樹*, 杉浦昌*, 藁科秀紀**, 長谷川幸治**, 山内健一*** Journal of Japanese Society for Replacement Arthroplasty 32: 185-186, 2002. |
---|
![]() |
Examination - of abrasion and the use of oxidation - UH1 case of the Bipolar type articular head prosthesis polyethylene 加来信広, 津村弘, 内田研, 原克利, 鳥巣岳彦 Journal of Japanese Society for Replacement Arthroplasty 32: 187-188, 2002. |
---|
![]() |
Abrasion of the withdrawal high doses crosslinked polyethylene socket in the long-term clinical practice 大西啓靖*, 岩城啓好**, 増田真吾*** Journal of Japanese Society for Replacement Arthroplasty 32: 189-190, 2002. |
---|
![]() |
Examination of the stem neck antetorsio corner counting using the X-rays axis representation simple after the THA technique 白須秀男, 山本謙吾, 松浦清人, 正岡利紀, 香取庸一, 澤田博文, 葛西直亮, 今給黎篤弘 Journal of Japanese Society for Replacement Arthroplasty 32: 191-192, 2002. |
---|
![]() |
About the bone-related impinge in the internal rotation direction after the THA by the acetabular roof setting position 鈴木康司*, 松原正明**, 神野哲也**, 麻生義則**, 森田定雄**, 宗田大**, 四宮謙一** Journal of Japanese Society for Replacement Arthroplasty 32: 193-194, 2002. |
---|
![]() |
stem antetorsio and thighbone antetorsio in the secondary coxarthropathy 松原正明, 鈴木康司, 神野哲也, 麻生義則, 宗田大, 四宮謙一 Journal of Japanese Society for Replacement Arthroplasty 32: 195-196, 2002. |
---|
![]() |
Change of the range of motion by the bone diameter of head in the total hip prosthesis 吉峰史博, 二木康夫 Journal of Japanese Society for Replacement Arthroplasty 32: 197-198, 2002. |
---|
![]() |
Plan before operation of the THA using the three-dimensional computer simulation 池渕充彦, 島本敬三, 保川英一, 前憲作, 庄司恭之, 安田浩成, 岡垣健太郎, 東隆 Journal of Japanese Society for Replacement Arthroplasty 32: 199-200, 2002. |
---|
![]() |
The effect that implant setting position defectiveness gives to dislocation development after the THA 西井孝, 菅野伸彦, 三木秀宣, 原口圭司, 萩尾圭介, 西原俊作, 岸田友紀, 吉川秀樹 Journal of Japanese Society for Replacement Arthroplasty 32: 201-202, 2002. |
---|
![]() |
It is examined the dislocation case after all total hip replacement 正岡利紀, 山本謙吾, 松浦清人, 香取庸一, 白須秀男, 澤田博文, 布田大介, 葛西直亮, 今給黎篤弘 Journal of Japanese Society for Replacement Arthroplasty 32: 203-204, 2002. |
---|
![]() |
It is examined the dislocation case after the THA technique in our hospital 岩田憲*, 森諭史*, 乗松尋道*, 松下誠司** Journal of Japanese Society for Replacement Arthroplasty 32: 205-206, 2002. |
---|
![]() |
Evaluation of X-rays in the anatomic position of the greater tubercle of humerus 高瀬勝己*, 小野彰夫*, 山本謙吾*, 今給黎篤弘*, Wayne Z. Burkhead Jr.** Journal of Japanese Society for Replacement Arthroplasty 32: 207-208, 2002. |
---|
![]() |
Histories of treatment for RA of Kudo-type person mechanic elbow joint type 5 中山憲, 高木治樹, 玉木茂行, 高塚和孝, 武田拓之 Journal of Japanese Society for Replacement Arthroplasty 32: 209-210, 2002. |
---|
![]() |
Clinical results of the MP artificial finger Seki replacement in patients with rheumatoid arthritis 三部順也*, 渡辺健*, 神谷鉄士*, 藤江剛*, 辻村宣克*, 今給黎篤弘** Journal of Japanese Society for Replacement Arthroplasty 32: 211-212, 2002. |
---|
![]() |
Examination of the artificial finger joint replacement for the traumatic phalangeal joint symptom (PIP joint) 内田理*, 十河敏晴*, 金川文俊*, 浜田佳孝*, 板東和寿*, 青山茂樹** Journal of Japanese Society for Replacement Arthroplasty 32: 213-214, 2002. |
---|
![]() |
Trochanteric fixed results using Dall-Miles cable grip system in our hospital 大楽勝之*, 石井政次*, 浜崎允*, 高木理彰**, 小林真司**, 山川正紀**, 川路博之**, 佐藤哲也**, 新田長生**, 井田英雄*** Journal of Japanese Society for Replacement Arthroplasty 32: 215-216, 2002. |
---|
![]() |
Histories of treatment for the femur fracture after the total hip replacement 中村伸一郎, 高木治樹, 玉木茂行, 高塚和孝, 中山憲, 武田拓之, 北折俊之 Journal of Japanese Society for Replacement Arthroplasty 32: 217-218, 2002. |
---|
![]() |
MRI after Total Hip Arthroplasty and the bipolar type total hip prosthesis 広瀬勲*1, 杉本英治*2, 近藤宰司*3, 草場敦*3, 伊東祐一*3, 逸見範幸*3, 前田昭彦*3, 黒木良克*4 Journal of Japanese Society for Replacement Arthroplasty 32: 219-220, 2002. |
---|
![]() |
A case which contralateral osteolysis reduced after the unilateral revision THA enforcement for aseptic loosening after both hip joints artificial head replacement 高橋和寛, 安永裕司, 久留隆史, 生田義和 Journal of Japanese Society for Replacement Arthroplasty 32: 221-222, 2002. |
---|
![]() |
Experience of artificial bone grafting for early osteolysis after THA surgery 川口洋, 坂本啓, 塩出速雄, 吉田真, 漆谷英禮 Journal of Japanese Society for Replacement Arthroplasty 32: 223-224, 2002. |
---|
![]() |
Results of the acetabulum side reimplantation with Impaction Allografting and the cement fixation-type socket 東隆, 安田浩成, 岡垣健太郎, 池淵充彦 Journal of Japanese Society for Replacement Arthroplasty 32: 225-226, 2002. |
---|
![]() |
Maneuver - to use support ring together with the rebuilding due to our invention - same kind bone in the artificial mortar reimplantation with the bone defect 糸満盛憲, 高平尚伸, 東計, 内山勝文, 宮部基, 那須野秀二 Journal of Japanese Society for Replacement Arthroplasty 32: 227-228, 2002. |
---|
![]() |
Results of Impaction bone grafting (the thigh side) in our hospital 石井政次*, 大楽勝之*, 浜崎允*, 高木理彰**, 小林真司**, 山川正紀**, 佐藤哲也**, 川路博之**, 新田長生**, 井田英雄*** Journal of Japanese Society for Replacement Arthroplasty 32: 229-230, 2002. |
---|
![]() |
A method of the reimplantation of the use of cement thighbone component for Failed hip prosthesis and medium-term results 木下勇*1, 田岡博明*1, 中野俊次*2, 高原茂之*2, 江川洋史*2, 安井夏生*2, 太田健吾*3, 河野邦一*4 Journal of Japanese Society for Replacement Arthroplasty 32: 231-232, 2002. |
---|
![]() |
Examination of the total hip prosthesis reimplantation using the distal fixed type cementless stem 近藤宰司*, 川内邦雄*, 広瀬勲*, 草場敦*, 伊東祐一*, 西岡一雄*, 田代一郎*, 逸見範幸*, 前田昭彦*, 黒木良克** Journal of Japanese Society for Replacement Arthroplasty 32: 233-234, 2002. |
---|
![]() |
A concept and results (the thigh side) of the THA re-substitution: Method using Wagner 菅野伸彦*1, 西井孝*1, 三木秀宣*1, 原口圭司*1, 西原俊作*1, 萩尾佳介*1, 岸田友紀*1, 吉川秀樹*1, 大園健二*2, 李勝博*2, 中村宣雄*3, 柿本明博*3, 小野秀文*4, 村井純子*4, 倉都滋之*4 Journal of Japanese Society for Replacement Arthroplasty 32: 235-236, 2002. |
---|
![]() |
Examination of the total knee prosthesis re-substitution case for the gonarthrosis 一戸貞文*, 吉村文孝*, 赤坂俊樹*, 嶋村正*, 本田恵**, 白倉義博**, 小野寺智彦*** Journal of Japanese Society for Replacement Arthroplasty 32: 237-238, 2002. |
---|
![]() |
Re-substitution for the infection after TKA 早川和恵, 中川研二, 安藤淳 Journal of Japanese Society for Replacement Arthroplasty 32: 239-240, 2002. |
---|
![]() |
Effect of the antibiotic-containing calcium phosphate bone cement in the artificial joint reimplantation 付岡正*, 鈴木昌彦*, 常泉吉一*, 渡辺英一郎*, 内海昌浩*, 守屋秀繁*, 金泰成**, 梅田智広***, 竹内啓素*** Journal of Japanese Society for Replacement Arthroplasty 32: 241-242, 2002. |
---|
![]() |
Examination of the initial solidity around the cementless total hip prosthesis stem 福井康人, 日下部虎夫, 松本憲和, 樋口哲生, 野崎貴子, 竹下博志, 山崎隆仁, 原邦夫, 岩破康博 Journal of Japanese Society for Replacement Arthroplasty 32: 243-244, 2002. |
---|
![]() |
- with HA/TCP coating and osteolysis of medium-term results - Socket, stem of the Anatomic total hip prosthesis for the Osteoarthritis of the hip concerned 山崎聡*, 増原建作*, 三木秀宣*, 冨士武史*, 斉藤正伸** Journal of Japanese Society for Replacement Arthroplasty 32: 245-246, 2002. |
---|
![]() |
Experience of the BiCONTACT THA in our hospital 白倉義博*, 本田惠*, 北川由佳**, 一戸貞文**, 小野寺智彦*** Journal of Japanese Society for Replacement Arthroplasty 32: 247-248, 2002. |
---|
![]() |
Use experience of the bone preservation type total hip prosthesis 濱裕, 比佐健二, 伊藤龍太郎, 小久保亜早子, 中小路拓 Journal of Japanese Society for Replacement Arthroplasty 32: 249-250, 2002. |
---|
![]() |
Was total hip prosthesis reimplantation - surface substitution type total hip replacement that a long term passed after Socket and cup surface replacement, and was performed able to keep a bone of the proximal thighbone? - 神宮司誠也, 野口康男, 首藤敏秀, 中島康晴, 山本卓明, 岩本幸英 Journal of Japanese Society for Replacement Arthroplasty 32: 251-252, 2002. |
---|
![]() |
One case that patellar component reversed after TKA 森久美子, 井上和彦, 橋本俊彦, 辻直樹 Journal of Japanese Society for Replacement Arthroplasty 32: 253-254, 2002. |
---|
![]() |
Examination of the iterative hemarthrosis case that occurred after the Total Knee Arthroplasty 王寺享弘*, 徳永真巳*, 宏洲士郎*, 吉本栄治*, 井手衆哉** Journal of Japanese Society for Replacement Arthroplasty 32: 255-256, 2002. |
---|
![]() |
Examination - second report - of the heterotopic bone formation to occur after the Total Knee Arthroplasty 宏洲士郎, 王寺享弘, 宮城哲, 徳永真巳, 吉本栄治, 小林晶 Journal of Japanese Society for Replacement Arthroplasty 32: 257-258, 2002. |
---|
![]() |
One patient who repeated dislocation after the Total Knee Arthroplasty 松浦正典, 吉門俊之, 中洲裕, 林成治 Journal of Japanese Society for Replacement Arthroplasty 32: 259-260, 2002. |
---|
![]() |
Histories of treatment for the component outskirts bone fracture after TKA 川島正幹, 宮本浩秀, 木全則文, 佐藤啓二 Journal of Japanese Society for Replacement Arthroplasty 32: 261-262, 2002. |
---|
![]() |
Pre-rear investigation of the pulmonary embolism after the Total Knee Arthroplasty 西口雅彦, 河野昌文, 末廣昌嗣, 川田英人, 安達信二, 田口厚 Journal of Japanese Society for Replacement Arthroplasty 32: 263-264, 2002. |
---|
![]() |
Use experience of Venous Foot Pump after the lower limbs person mechanic joint operation 市場厚志*, 岸本郁男*, 小田幸作*, 後藤研三** Journal of Japanese Society for Replacement Arthroplasty 32: 265-266, 2002. |
---|
![]() |
We experience the use of the non-ablution self blood collection device after the operation 秋山典宏, 岩崎廉平, 河本正昭, 杉谷繁樹, 仮元幹雄, 宗和隆, 井上茂亮 Journal of Japanese Society for Replacement Arthroplasty 32: 267-268, 2002. |
---|